5.4.12
Setting multiple parameters as a batch
Parameter settings are changed as a batch. Those include communication parameter settings for the Mitsubishi Electric's
human machine interface (GOT) connection and the parameter setting for the rated frequency settings of 50 Hz/60 Hz and
acceleration/deceleration time.
Pr.
Name
999
Automatic parameter setting
E431
*1
The read value is always "9999".
 Automatic parameter setting (Pr.999)
• Select which parameters to automatically set from the table below, and set them in Pr.999. Multiple parameter settings are
changed automatically. Refer to
Pr.999
Setting
1
Sets the standard monitor indicator setting of PID control.
2
Automatically sets the monitor indicator for PID control.
10
Automatically sets the communication parameters for the GOT connection with a PU connector ("Controller Type" in GOT:
FREQROL 500/700/800, SENSORLESS SERVO)
11
Automatically sets the communication parameters for the GOT connection with RS-485 terminals ("Controller Type" in GOT:
FREQROL 500/700/800, SENSORLESS SERVO)
12
Automatically sets the communication parameters for the GOT connection with a PU connector ("Controller Type" in GOT:
FREQROL 800 (Automatic Negotiation))
13
Automatically sets the communication parameters for the GOT connection with RS-485 terminals ("Controller Type" in GOT:
FREQROL 800 (Automatic Negotiation))
20
50 Hz rated frequency
21
60 Hz rated frequency
NOTE
• If the automatic setting is performed with Pr.999 or the automatic parameter setting mode, the settings including the
changed parameter settings (changed from the initial setting) will be automatically changed. Before performing the
automatic setting, confirm that changing the parameters will not cause any problem.
Initial value
Setting range
*1
1
9999
2
10
11
12
13
20
21
9999
page 175
for the list of parameters that are changed automatically.
Description
Sets the related parameters of the rated frequency according to the power supply frequency
Description
Standard PID display setting
Extended PID display setting
GOT initial setting (PU
connector)
GOT initial setting (RS485
terminals)
GOT initial setting (PU
connector)
GOT initial setting (RS-485
terminal)
50 Hz rated frequency
60 Hz rated frequency
No action
5. PARAMETERS
5.4 (E) Environment setting parameters
3
4
5
"Controller
Type" in GOT:
FREQROL 500/
5
700/800,
SENSORLESS
SERVO
5
"Controller
Type" in GOT:
FREQROL 800
(Automatic
Negotiation)
6
7
8
9
10
173