Function
Pr.
PID control
1132
1133
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
PLC function
1150
to
1199
PID gain tuning
1211
1212
1213
1214
1215
1216
1217
1218
1219
1300
to
1343
1346
130
5. PARAMETERS
5.1 Parameter List
Pr.
Name
group
A626
Pre-charge change
increment amount
A666
Second pre-charge
change increment
amount
A670
Second PID display bias
Simple
Simple
Simple
coefficient
A671
Second PID display bias
Simple
Simple
Simple
analog value
A672
Second PID display gain
Simple
Simple
Simple
coefficient
A673
Second PID display gain
Simple
Simple
Simple
analog value
A664
Second PID set point/
deviation input selection
A665
Second PID measured
value input selection
A640
Second PID unit
selection
A641
Second PID upper limit
A642
Second PID lower limit
A643
Second PID deviation
limit
A644
Second PID signal
operation selection
A661
Second output
interruption detection
time
A662
Second output
interruption detection
level
A663
Second output
interruption cancel level
A810
PLC function user
to
parameters 1 to 50
A859
A690
PID gain tuning timeout
time
A691
Step manipulated
amount
A692
Step response sampling
cycle
A693
Timeout time after the
maximum slope
A694
Limit cycle output upper
limit
A695
Limit cycle output lower
limit
A696
Limit cycle hysteresis
A697
PID gain tuning setting
A698
PID gain tuning start/
status
N500
Communication option parameters.
to
For details, refer to the Instruction Manual of the option.
N543
A457
PID lower limit operation
detection time
Setting range
Minimum
setting
increments
0 to 100%, 9999
0.01%
0 to 100%, 9999
0.01%
0 to 500, 9999
0.01
0 to 300%
0.1%
0 to 500, 9999
0.01
0 to 300%
0.1%
1 to 5
1
1 to 5, 101 to 105
1
0 to 43, 9999
1
0 to 100%, 9999
0.1%
0 to 100%, 9999
0.1%
0 to 100%, 9999
0.1%
0 to 7, 10 to 17
1
0 to 3600 s, 9999
0.1 s
0 to 590 Hz
0.01 Hz
900 to 1100%
0.1%
0 to 65535
1
1 to 9999 s
1 s
900 to 1100%
0.1%
0.01 to 600 s
0.01 s
1 to 9999 s
1 s
900 to 1100%
0.1%
900 to 1100%
0.1%
0.1 to 10%
0.1%
0, 100 to 102, 111,
1
112, 121, 122,
200 to 202, 211, 212,
221, 222
(0), 1, 8, (9, 90 to 96)
1
0 to 900 s
1 s
Initial value
Refer
Customer
to
setting
page
9999
424
9999
424
9999
421
20%
421
9999
421
100%
421
2
396
3
396
9999
396
9999
396
9999
396
9999
396
0
396
1
396
0 Hz
396
1000%
396
0
463
100 s
415
1000%
415
1 s
415
10 s
415
1100%
415
1000%
415
1%
415
0
415
0
415
9999