 Changing the motor constants (If setting the Pr.92 and Pr.93 motor
constants in units of [Ω])
• Set Pr.71 as shown below.
Applicable motor
Standard motor
5
Constant-torque motor
15
• Set given values as the motor constant parameters.
Iq = torque current, I
100 =
Iq =
I
2
- I
2
100
0
First
Second
motor Pr.
motor Pr.
82
455
Motor excitation current
(No-load current)
90
458
Motor constant (r1)
91
459
Motor constant (r2)
92
460
Motor constant (1)
93
461
Motor constant (2)
94
462
Motor constant (m)
859
860
Torque current/Rated PM
motor current
298
560
Frequency search gain
*1
For the FR-F860-00680 or lower.
*2
For the FR-F860-01080 or higher.
NOTE
• If "star connection" or "delta connection" is incorrectly selected in Pr.71, Advanced magnetic flux vector control is not
performed normally.
• If "9999" is set, tuning data will be invalid and the motor constant values for standard motors are used.
Pr.71 setting
Star connection motor
Delta connection motor
6
16
rated current, I
no load current
0 =
Name
0 to 500 A, 9999
0 to 3600 A, 9999
0 to 50 Ω, 9999
0 to 400 mΩ, 9999
0 to 50 Ω, 9999
0 to 400 mΩ, 9999
0 to 50 Ω, 9999
0 to 3600 mΩ, 9999
0 to 50 Ω, 9999
0 to 3600 mΩ, 9999
0 to 500 Ω, 9999
0 to 100 Ω, 9999
0 to 500 A, 9999
0 to 3600 A, 9999
0 to 32767, 9999
Setting range
Setting increments
*1
0.01 A
*2
0.1 A
*1
0.001 Ω
*2
0.01 mΩ
*1
0.001 Ω
*2
0.01 mΩ
*1
0.001 Ω
*2
0.01 mΩ
*1
0.001 Ω
*2
0.01 mΩ
*1
0.01 Ω
*2
*1
0.01 A
*2
0.1 A
1
Initial value
9999
*1
*2
*1
*2
*1
*2
*1
*2
*1
*2
*1
*2
5. PARAMETERS
5.10 (C) Motor constant parameters
3
4
5
5
5
6
7
8
9
10
361