Mitsubishi Electric 800 Series Instruction Manual page 470

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

 Analog source (monitored item) selection
• Select the analog sources (monitored items) to be set to Pr.1027 to Pr.1034 from the table below.
Setting
Monitored item
value
1
Output frequency/speed
2
Output current
3
Output voltage
5
Frequency setting value/
speed setting
6
Running speed
7
Motor torque
8
Converter output voltage
For manufacturer setting
*5
9
10
Electronic thermal O/L relay
load factor
11
Output current peak value
12
Converter output voltage peak
value
13
Input power
14
Output power
17
Load meter
18
Motor excitation current
20
Cumulative energization time
23
Actual operation time
24
Motor load factor
34
Motor output
40
PLC function user monitor 1
41
PLC function user monitor 2
42
PLC function user monitor 3
52
PID set point
53
PID measured value
54
PID deviation
61
Motor thermal load factor
62
Inverter thermal load factor
64
PTC thermistor resistance
67
PID measured value 2
Emergency drive status
*5
68
69
PID input pressure value
81
BACnet reception status
82
BACnet token pass counter
*1
"*" shows a monitored item with a high-speed sampling cycle.
*2
"" shows that the display with a minus sign is available.
*3
Indicates a criterion at 100% when the analog trigger is set.
*4
Refer to Terminal CA/AM Full-scale value
*5
The setting is available only for standard models.
Rated motor frequency  120 / number of motor poles
*6
*7
The reference current for the trigger level is as follows.
Model FR-F860-[] 00027 00061 00090 00170 00320 00450 00680 01080 01440 01670 02430 02890 03360 04420
Trigger level
1.7
4
reference current
(A)
*1
Minus
Trigger
sign
level
*2
display
criterion
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
65535
65535
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
Pr.561
*4
65535
*4
65535
65535
(page
284).
6.1
12
22
33
Setting
Monitored item
value
*3
83
BACnet valid APDU counter
84
BACnet communication error
counter
85
BACnet terminal CA output
level
86
BACnet terminal AM output
level
87
Remote output value 1
88
Remote output value 2
89
Remote output value 3
90
Remote output value 4
91
PID manipulated variable
92
Second PID set point
93
Second PID measured value
94
Second PID deviation
95
Second PID measured value 2
96
Second PID manipulated
variable
98
Control circuit temperature
201
*Output frequency
202
*U Phase Output Current
203
*V Phase Output Current
204
*W Phase Output Current
205
*Converter Output Voltage
206
*Output Current (all three
phases)
207
*Excitation Current(A)
208
*Torque Current(A)
209
Terminal 2
210
Terminal 4
211
Terminal 1
212
*Excitation Current (%)
213
*Torque Current (%)
230
*Output Frequency (signed)
231
*Motor Speed
232
*Speed Command
237
*Excitation Current Command
238
*Torque Current Command
55
84
104
*1
Minus
Trigger
sign
*2
display
criterion
65535
65535
100%
100%
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
Pr.84
*7
*7
*7
1000 V
*7
*7
*7
100%
100%
100%
100%
100%
Pr.84
*6
*6
100%
100%
131
152
221
255
5. PARAMETERS
5.11 (A) Application parameters
3
level
4
*3
5
5
5
6
7
8
9
10
304
469

Advertisement

Table of Contents
loading

Table of Contents