Mitsubishi Electric 800 Series Instruction Manual page 154

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Pr.
Name
893
Energy saving monitor reference
(motor capacity)
918
Terminal 1 gain frequency (speed) 60 Hz
―: Not changed
*1
Initial value for the FR-F860-00680 or lower.
*2
Initial value for the FR-F860-01080 or higher.
*3
110% for SLD, 120% for LD (Refer to Pr.570 Multiple rating setting
*4
The Pr.702 Maximum motor frequency is used as the maximum motor frequency (rotations per minute). When Pr.702 ="9999 (initial value)",
the Pr.84 Rated motor frequency is used as the maximum motor frequency (rotations per minute).
*5
The setting value is converted from frequency to rotations per minute. (The value after the conversion differs according to the number of motor
poles.)
NOTE
• If PM parameter initialization is performed in rotations per minute (Pr.998 = "8009 or 9009"), the parameters not listed in
the table and the monitored items are also set and displayed in rotations per minute.
Setting
Induction motor
PM motor
(rotations per
minute)
0
8009, 9009
(initial value)
Inverter capacity
Motor capacity (Pr.80)
Pr.84
page
PM motor
(frequency)
8109, 9109
Pr.84
167.)
Setting
increments
3
8009,
0, 8109,
4
9009
9109
*1
0.01 kW
*2
0.1 kW
1 r/min
0.01 Hz
5
5
5
6
7
8
9
10
153
5. PARAMETERS