5.6.6
JOG operation
The frequency and acceleration/deceleration time for JOG operation can be set. JOG operation is possible in both External
operation and PU.
JOG operation can be used for conveyor positioning, test run, etc.
Pr.
Name
15
Jog frequency
D200
16
Jog acceleration/
F002
deceleration time
Note that these parameters are categorized as a simple mode parameter when the LCD operation panel or the parameter unit
is used.
*1
The Pr.20 initial value is set to 60 Hz.
 JOG operation in the External operation
• Operation can be started and stopped by the start signals (STF and STR signals) when the Jog operation selection (JOG)
signal is ON. (For the operation method, refer to
• While the JOGF or JOGR signal is input, the Pr.15 Jog frequency setting is used for operation. The rotation is forward
while the JOGF signal is input, and the rotation is reverse while the JOGR signal is input. (Direct JOG function)
• Use Pr.16 Jog acceleration/deceleration time to set the acceleration/deceleration time during JOG operation.
• For each signal, refer to the following table and assign the function by Pr.178 to Pr.189 (Input terminal function
selection).
Input signal
Pr.178 to Pr.189 settings
JOG
5 (Pr.185 initial value)
JOGF
57
JOGR
58
Output frequency (Hz)
Pr.20
Pr.15
setting range
JOG signal
Forward rotation STF
Reverse rotation STR
224
5. PARAMETERS
5.6 (D) Operation command and frequency command
Initial value
Setting range
5 Hz
0 to 590 Hz
0.5 s
0 to 3600 s
Forward
rotation
Reverse
rotation
Pr.16
ON
ON
ON
Sets the frequency during JOG operation.
Sets motor acceleration/deceleration time during JOG
operation. For the acceleration/deceleration time, set the time
until the frequency
reference frequency is reached.
The acceleration/deceleration times cannot be set separately.
page
104.)
Output frequency (Hz)
Pr.20
Pr.15
Forward
rotation
setting range
Time
Pr.16
ON
JOGF signal
JOGR signal
Description
*1
set to Pr.20 Acceleration/deceleration
Time
Reverse
rotation
ON