 Energy saving monitor list
• The items that can be monitored on the power saving monitor (Pr.52, Pr.54, Pr.158, Pr.774 to Pr.776 = "50") are indicated
below. (Only [1 Power saving] and [3 Average power saving] can be set to Pr.54 (terminal CA) and Pr.158 (terminal AM).)
Energy saving
monitored item
1
Power saving
2
Power saving rate
3
Average power
saving
4
Average power
saving rate
5
Average power cost
savings
• The items that can be monitored on the cumulative energy saving monitor (Pr.52, Pr.774 to Pr.776 = "51") are indicated
below. (The monitor value of the cumulative monitor can be shifted to the right with Pr.891 Cumulative power monitor
digit shifted times.)
Energy saving
monitored item
6
Power saving
amount
7
Power cost saving
8
Annual power
saving amount
9
Annual power cost
savings
*1
For communication, (RS-485 communication, communication option), the display increments are 1. For example, "10.00 kWh" is displayed as
"10" for communication data.
*2
When using the LCD operation panel or the parameter unit, "kW" is displayed
*3
The increment differs according to capacities. (FR-F860-00680 or lower/FR-F860-01080 or higher.)
292
5. PARAMETERS
5.8 (M) Monitor display and monitor output signal
Description and formula
The difference between the estimated value of the
required power during commercial power supply
operation and the input power calculated with the
inverter.
Power supply during commercial power supply
operation - input power monitor
The power saving ratio with the commercial power
supply operation as 100%.
[1 Power saving]
Power during commercial power supply operation
The power saving ratio with Pr.893 as 100%.
[1 Power saving]
× 100
Pr.893
The average power saving per hour during a
predetermined time (Pr.897).
∑ ([1 Power saving] × ∆t)
Pr.897
The average power saving ratio with the commercial
power supply operation as 100%.
∑ ([2 Power saving rate] × ∆t)
Pr.897
The average power saving ratio with Pr.893 as 100%.
[3 Average power saving]
× 100
Pr.893
The average power saving in terms of cost.
[3 Average power saving]  Pr.896
Description and formula
The cumulative power saving is added up per hour.
∑([1 Power saving]  ∆t)
The power saving amount in terms of cost.
[6 Power saving amount]  Pr.896
Estimated value of annual power saving amount.
[6 Power saving amount]
× 24 × 365 ×
Operation time during power
saving accumulation
Annual power saving amount in terms of cost.
[8 Annual power saving amount]  Pr.896
Increment
0.01 kW/0.1
*3
kW
0.1%
×100
0.01 kWh/
0.1 kWh
0.1%
× 100
*3
0.01/0.1
Increment
0.01 kWh/
0.1 kWh
*1*2*3
0.01/0.1
0.01 kWh/
0.1 kWh
Pr.899
*1*2*3
100
0.01/0.1
Parameter setting
Pr.895
Pr.896
Pr.897
9999
9999
0
1
9999
9999
0 to
*3
1000 h
0
1
-
0 to
500
Parameter setting
Pr.895
Pr.896
Pr.897
9999
*1*3
0 to
500
9999
*1*3
0 to
500
Pr.899
Pr.899
9999
0 to
100%