Mitsubishi Electric 800 Series Instruction Manual page 399

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Pr.
753
Second PID action
A650
selection
754
Second PID control
A652
automatic switchover
frequency
755
Second PID action set point 9999
A651
756
Second PID proportional
A653
band
757
Second PID integral time
A654
758
Second PID differential
A655
time
1140
Second PID set point/
A664
deviation input selection
1141
Second PID measured
A665
value input selection
1143
Second PID upper limit
A641
1144
Second PID lower limit
A642
1145
Second PID deviation limit
A643
1146
Second PID signal
A644
operation selection
1147
Second output interruption
A661
detection time
1148
Second output interruption
A662
detection level
1149
Second output interruption
A663
cancel level
398
5. PARAMETERS
5.11 (A) Application parameters
Name
Initial value
0
9999
100
1 s
9999
2
3
9999
9999
9999
0
1 s
0 Hz
1000%
Setting range
0, 10, 11, 20, 21,
Refer to Pr.128.
50, 51, 60, 61, 70,
71, 80, 81, 90, 91,
100, 101, 1000,
1001, 1010, 1011,
2000, 2001, 2010,
2011
0 to 590 Hz, 9999
Refer to Pr.127.
0 to 100%, 9999
Refer to Pr.133.
0.1 to 1000%,
Refer to Pr.129.
9999
0.1 to 3600 s,
Refer to Pr.130.
9999
0.01 to 10 s, 9999 Refer to Pr.134.
1 to 5
Refer to Pr.609.
1 to 5, 101 to 105
Refer to Pr.610.
0 to 100%, 9999
Refer to Pr.131.
0 to 100%, 9999
Refer to Pr.132.
0 to 100%, 9999
Refer to Pr.553.
(Y205 signal is
output.)
0 to 7, 10 to 17
Refer to Pr.554.
0 to 3600 s, 9999
Refer to Pr.575.
0 to 590 Hz
Refer to Pr.576.
900 to 1100%
Refer to Pr.577.
Description
Set the second PID control.
For how to enable the second PID
control, refer to
page
412.