Mitsubishi Electric 800 Series Instruction Manual page 394

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

• Convert a bit image (binary) of the trigger factor into a decimal value, and set the value in Pr.1471.
Pr.1471
bit 3
Decimal
Binary
15
1111
14
1110
13
1101
12
1100
11
1011
10
1010
9
1001
8
1000
7
0111
6
0110
5
0101
4
0100
3
0011
2
0010
1
0001
0
0000
: Trigger enabled,
: Trigger disabled
bit
15
7
0 0 0 0 0 0 0 0 0 0 0 0 1 0 0
Pr.1471 setting
Set the decimal converted
value of the bit image.
bit 2
bit 1
bit 0
0
1
bit 0 Start trigger
bit 1 Output current trigger
bit 2 PID upper/lower limit trigger
bit 3 Load warning trigger
5. PARAMETERS
5.11 (A) Application parameters
3
4
5
5
5
6
7
8
9
10
393