Mitsubishi Electric 800 Series Instruction Manual page 58

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

NICHIFU Co., Ltd.
2
Wire gauge (mm
)
Crimp terminal part No.
0.3 to 0.75
BT 0.75-11
3.
Insert the wires into a socket.
NOTE
• When using stranded wires without a crimp terminal, twist enough to avoid short circuit with a nearby terminals or wires.
• Place the flathead screwdriver vertical to the open/close button. In case the blade tip slips, it may cause an inverter damage
or injury.
 Wire removal
Pull the wire while pushing the open/close button all the way down firmly with a flathead screwdriver.
NOTE
• Pulling out the wire forcefully without pushing the open/close button all the way down may damage the terminal block.
• Use a small flathead screwdriver (tip thickness: 0.4 mm/tip width: 2.5 mm). If a flathead screwdriver with a narrow tip is
used, terminal block may be damaged. Commercially available products (as of October 2020)
Name
Model
Screwdriver
SZF
Phoenix Contact Co., Ltd.
0- 0,4  2,5
• Place the flathead screwdriver vertical to the open/close button. In case the blade tip slips, it may cause an inverter damage
or injury.
Insulation cap part No.
VC 0.75
When using a single wire or stranded wires without a crimp terminal, push the
open/close button all the way down with a flathead screwdriver, and insert the
wire.
Open/close button
Flathead screwdriver
Manufacturer
Crimping tool model
No.
NH 69
Open/close button
Flathead screwdriver
2. INSTALLATION AND WIRING
2.6 Control circuit
3
2
3
4
5
6
7
8
9
10
57