Mitsubishi Electric 800 Series Instruction Manual page 153

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

 PM parameter initialization list
• The parameter settings in the following table are changed to the settings required to perform PM motor control by selecting
PM motor control with the IPM parameter initialization mode on the operation panel or with Pr.998 PM parameter
initialization.
• Performing parameter clear or all parameter clear sets back the parameter settings to the settings required to drive an
induction motor.
Pr.
Name
1
Maximum frequency
4
Multi-speed setting (high speed)
9
Electronic thermal O/L relay
13
Starting frequency
15
Jog frequency
18
High speed maximum frequency
20
Acceleration/deceleration
reference frequency
22
Stall prevention operation level
37
Speed display
55
Frequency monitoring reference
56
Current monitoring reference
71
Applied motor
80
Motor capacity
81
Number of motor poles
84
Rated motor frequency
125
Terminal 2 frequency setting gain
(903)
frequency
126
Terminal 4 frequency setting gain
(905)
frequency
144
Speed setting switchover
240
Soft-PWM operation selection
263
Subtraction starting frequency
266
Power failure deceleration time
switchover frequency
374
Overspeed detection level
390
% setting reference frequency
505
Speed setting reference
557
Current average value monitor
signal output reference current
870
Speed detection hysteresis
885
Regeneration avoidance
compensation frequency limit
value
152
5. PARAMETERS
5.2 Control method
Induction motor
PM motor
(rotations per
0
8009, 9009
(initial value)
Maximum motor
*1
120 Hz
rotations per minute
*2
60 Hz
60 Hz
Pr.84
Inverter rated current
Pr.84 10%
0.5 Hz
Pr.84 10%
5 Hz
*1
120 Hz
*2
60 Hz
60 Hz
Pr.84
Short-time motor torque
*3
110%
0
0
60 Hz
Pr.84
Inverter rated current
Pr.859
0
9999
9999
9999
60 Hz
Pr.84
60 Hz
Pr.84
4
Pr.81 +100
1
0
60 Hz
Pr.84
60 Hz
Pr.84
9999
Maximum motor
rotations per minute
+10 Hz
60 Hz
Pr.84
60 Hz
Pr.84
Inverter rated current
Pr.859
0 Hz
0.5 Hz
Pr.84 10%
6 Hz
Setting
PM motor
(frequency)
minute)
8109, 9109
Maximum motor
*4
*4
frequency
Pr.84
Pr.84 10%
Pr.84 10%
Pr.84
Pr.84
Pr.859
Pr.84
Pr.84
Pr.81
Pr.84
Pr.84
Maximum motor
frequency +10 Hz
*4*5
Pr.84
Pr.84
Pr.859
0.5 Hz
*5
Pr.84 10%
Setting
increments
8009,
0, 8109,
9009
9109
1 r/min
0.01 Hz
1 r/min
0.01 Hz
*1
0.01 A
*2
0.1 A
1 r/min
0.01 Hz
1 r/min
0.01 Hz
1 r/min
0.01 Hz
1 r/min
0.01 Hz
0.1%
1
1 r/min
0.01 Hz
*1
0.01 A
*2
0.1 A
1
*1
0.01 kW
*2
0.1 kW
1
1 r/min
0.01 Hz
1 r/min
0.01 Hz
1 r/min
0.01 Hz
1
1
1 r/min
0.01 Hz
1 r/min
0.01 Hz
1 r/min
0.01 Hz
*4
1 r/min
0.01 Hz
0.01 Hz
*1
0.01 A
*2
0.1 A
1 r/min
0.01 Hz
1 r/min
0.01 Hz

Advertisement

Table of Contents
loading

Table of Contents