Mitsubishi Electric 800 Series Instruction Manual page 121

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Function
Pr.
Second motor
450
constants
453
454
455
456
457
458
459
460
461
462
463
Remote output
495
496
497
498
502
Maintenance
503
504
505
506
*8
507
508
514
*8
515
*8
521
522
120
5. PARAMETERS
5.1 Parameter List
Pr.
Name
group
C200
Second applied motor
C201
Second motor capacity
C202
Number of second motor
poles
C225
Second motor excitation
current
C204
Rated second motor
voltage
C205
Rated second motor
frequency
C220
Second motor constant
(R1)
C221
Second motor constant
(R2)
C222
Second motor constant
(L1) / d-axis inductance
(Ld)
C223
Second motor constant
(L2) / q-axis inductance
(Lq)
C224
Second motor constant
(X)
C210
Second motor auto
tuning setting/status
M500
Remote output selection
M501
Remote output data 1
M502
Remote output data 2
A804
PLC function flash
memory clear
N013
Stop mode selection at
communication error
E710
Maintenance timer 1
E711
Maintenance timer 1
warning output set time
M001
Speed setting reference
E705
Display estimated main
circuit capacitor residual
life
E706
Display/reset ABC1 relay
contact life
E707
Display/reset ABC2 relay
contact life
H324
Emergency drive
dedicated retry waiting
time
H322
Emergency drive
dedicated retry count
H194
Output short-circuit
detection
G105
Output stop frequency
Setting range
Minimum
setting
increments
0, 1, 3 to 6, 13 to 16,
1
8093, 8094, 9090,
9093, 9094, 9999
*2
0.4 to 55 kW, 9999
0.01 kW
*3
0 to 3600 kW, 9999
0.1 kW
2, 4, 6, 8, 10, 12, 9999 1
*2
0 to 500 A, 9999
0.01 A
*3
0 to 3600 A, 9999
0.1 A
0 to 1000 V
0.1 V
10 to 400 Hz, 9999
0.01 Hz
*2
0 to 50 , 9999
0.001 
*3
0 to 400 m, 9999
0.01 m
*2
0 to 50 , 9999
0.001 
*3
0 to 400 m, 9999
0.01 m
*2
0 to 6000 mH, 9999
0.1 mH
*3
0 to 400 mH, 9999
0.01 mH
*2
0 to 6000 mH, 9999
0.1 mH
*3
0 to 400 mH, 9999
0.01 mH
0 to 100%, 9999
*2
0.1%
0.01%
0, 1, 11, 101
1
0, 1, 10, 11
1
0 to 4095
1
0 to 4095
1
0 to 9999
1
0 to 4
1
0 (1 to 9998)
1
0 to 9998, 9999
1
1 to 590 Hz
0.01 Hz
(0 to 100%)
1%
0 to 100%
1%
0 to 100%
1%
0.1 to 600 s, 9999
0.1 s
1 to 200, 9999
1
0, 1
1
0 to 590 Hz, 9999
0.01 Hz
Initial value
Refer
to
page
9999
351
*2
9999
353,
363
*3
9999
353,
363
9999
353
*2
*3
575 V
353,
363
9999
353,
363
*2
9999
353,
363,
*3
454
*2
9999
353
*3
*2
9999
353,
363
*3
9999
353,
*2
363
*3
9999
353
*3
0
353,
363,
454
0
310
0
310
0
310
0
463
0
478
0
186
9999
186
60 Hz
272
100%
182
100%
182
100%
182
9999
245
1
245
0
240
9999
548
Customer
setting

Advertisement

Table of Contents
loading

Table of Contents