Mitsubishi Electric 800 Series Instruction Manual page 126

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Function
Pr.
Pr.
group
PID pre-charge
760
A616
function
761
A617
762
A618
763
A619
764
A620
765
A656
766
A657
767
A658
768
A659
769
A660
Monitor
774
M101
function
775
M102
776
M103
777
A681
T053
778
A682
T054
779
N014
791
F070
792
F071
799
M520
800
G200
815
H710
Adjustment
820
G211
function
821
G212
822
T003
824
G213
825
G214
827
G216
828
G224
830
G311
831
G312
832
T005
834
G313
835
G314
837
G316
Name
Pre-charge fault
0, 1
selection
Pre-charge ending level
0 to 100%, 9999
Pre-charge ending time
0 to 3600 s, 9999
Pre-charge upper
0 to 100%, 9999
detection level
Pre-charge time limit
0 to 3600 s, 9999
Second pre-charge fault
0, 1
selection
Second pre-charge
0 to 100%, 9999
ending level
Second pre-charge
0 to 3600 s, 9999
ending time
Second pre-charge
0 to 100%, 9999
upper detection level
Second pre-charge time
0 to 3600 s, 9999
limit
Operation panel monitor
1 to 3, 5 to 14, 17, 18,
selection 1
20, 23 to 25, 34, 38, 40
to 45, 50 to 57, 61, 62,
Operation panel monitor
64, 67 to 69,
selection 2
81 to 96, 98, 100, 9999
Operation panel monitor
selection 3
4 mA input check
0 to 590 Hz, 9999
operation frequency
4 mA input check filter
0 to 10 s
Operation frequency
0 to 590 Hz, 9999
during communication
error
Acceleration time in low-
0 to 3600 s, 9999
speed range
Deceleration time in low-
0 to 3600 s, 9999
speed range
Pulse increment setting
0.1, 1, 10, 100, 1000
for output power
kWh
Control method
9, 20, 109, 110
selection
Torque limit level 2
0 to 400%, 9999
Speed control P gain 1
0 to 1000%
Speed control integral
0 to 20 s
time 1
Speed setting filter 1
0 to 5 s, 9999
Torque control P gain 1
0 to 500%
(current loop
proportional gain)
Torque control integral
0 to 500 ms
time 1 (current loop
integral time)
Torque detection filter 1
0 to 0.1 s
Parameter for manufacturer setting. Do not set.
Speed control P gain 2
0 to 1000%, 9999
Speed control integral
0 to 20 s, 9999
time 2
Speed setting filter 2
0 to 5 s, 9999
Torque control P gain 2
0 to 500%, 9999
(current loop
proportional gain)
Torque control integral
0 to 500 ms, 9999
time 2 (current loop
integral time)
Torque detection filter 2
0 to 0.1 s, 9999
Setting range
Minimum
setting
increments
1
0.1%
0.1 s
0.1%
0.1 s
1
0.1%
0.1 s
0.1%
0.1 s
1
1
1
0.01 Hz
0.01 s
0.01 Hz
0.1 s
0.1 s
0.1 kWh
1
0.1%
1%
0.001 s
0.001 s
1%
0.1 ms
0.001 s
1%
0.001 s
0.001 s
1%
0.1 ms
0.001 s
Initial value
Refer
Customer
to
setting
page
0
424
9999
424
9999
424
9999
424
9999
424
0
424
9999
424
9999
424
9999
424
9999
424
9999
274
9999
274
9999
274
9999
338
0 s
338
9999
478
9999
190
9999
190
1 kWh
315
20
145
9999
190
25%
155
0.333 s
155
9999
326
50%
155
40 ms
155
0 s
158
9999
155
9999
155
9999
326
9999
155
9999
155
9999
158
5. PARAMETERS
5.1 Parameter List
3
4
5
5
5
6
7
8
9
10
125

Advertisement

Table of Contents
loading

Table of Contents