Mitsubishi Electric 800 Series Instruction Manual page 164

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Pr.75 setting
1000
When the start signal is OFF.
1001
When the protective function is activated
and the start signal is OFF.
1002
When the start signal is OFF.
1003
When the protective function is activated
and the start signal is OFF.
1014
When the start signal is OFF.
1015
When the protective function is activated
and the start signal is OFF.
1016
When the start signal is OFF.
1017
When the protective function is activated
and the start signal is OFF.
1100
When the start signal is OFF.
1101
When the protective function is activated
and the start signal is OFF.
1102
When the start signal is OFF.
1103
When the protective function is activated
and the start signal is OFF.
1114
When the start signal is OFF.
1115
When the protective function is activated
and the start signal is OFF.
1116
When the start signal is OFF.
1117
When the protective function is activated
and the start signal is OFF.
*3
The setting is available for the FR-F860-01080 or higher.
 Reset selection (P.E100)
• While P.E100 = "1", or Pr.75 = "1, 3, 15, 17, 101, 103, 115, or 117", the reset command input is enabled (using the RES
signal or through communication) only when the protective function is activated.
• While P.E100 = "2" or Pr.75 = "1000, 1002, 1014, 1016, 1100, 1102, 1114, or 1116", the reset command input is enabled
(using the RES signal or through communication) only when the start signal is OFF.
• While P.E100 = "3" or Pr.75 = "1001, 1003, 1015, 1017, 1101, 1103, 1115, or 1117", the reset command input is enabled
(using the RES signal or through communication) only when the protective function is activated with the start signal OFF.
NOTE
• When the RES signal is input during operation, the motor coasts since the inverter being reset shuts off the output. Also,
the cumulative value of the electronic thermal relay is cleared.
• When "reset input always enabled" is selected, the reset key on the PU is enabled only when the protective function is
activated.
• The following table shows applicable start commands. (When both the STF and STR signals are ON, the start signal status
is OFF.)
Start signal input interface
External terminal
PU
Communication
• During emergency drive operation, reset input is always enabled regardless of the reset selection setting.
 Disconnected PU detection (P.E101)
• When the inverter detects that the PU (operation panel/parameter unit) is disconnected from the inverter for 1 second or
more while P.E101 or Pr.75 is set to shut off the inverter output upon disconnection of the PU, the PU disconnection
("E.PUE") indication is displayed and the inverter output is shut off.
NOTE
• When the PU has been disconnected since before power-ON, the output is not shut off.
• To restart, confirm that the PU is connected and then reset.
Reset input
Operation after PU
disconnection is
Operation continues.
Inverter output shutoff
Operation continues.
Inverter output shutoff
Operation continues.
Inverter output shutoff
Operation continues.
Inverter output shutoff
X13, X28, JOGF, JOGR, STF, or STR
Forward/reverse rotation command given by pressing the FWD/REV key
X13, X28, STF, or STR
PU stop function
detected
Disabled
Enabled
Disabled
Enabled
Applicable start signal
5.4 (E) Environment setting parameters
Reset limit
function
3
Disabled
4
5
5
*3
Enabled
5
6
7
8
9
10
163
5. PARAMETERS