Mitsubishi Electric 800 Series Instruction Manual page 46

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

• 600 V class (575 V input power supply, with a power factor improving AC or DC reactor)
Applicable
Terminal
inverter model
screw
*2
FR-F860-[ ]
size
00027 to 00090
M4
00170
M4
00320
M5
00450
M6
00680
M8
01080
M8
01440
M10
01670
M10
02430
M10
02890
M12(M10)
03360
M12(M10)
04420
M12(M10)
Applicable
Terminal
inverter model
screw
*2
FR-F860-[ ]
size
00027 to 00090
M4
00170
M4
00320
M5
00450
M6
00680
M8
01080
M8
01440
M10
01670
M10
02430
M10
02890
M12(M10)
03360
M12(M10)
04420
M12(M10)
*1
The cables used should be 75°C copper cables. (For the use in the United States or Canada, refer to "Instructions for UL and cUL" in the
Instruction Manual (Startup) or Instruction Manual (Hardware).)
*2
The terminal screw size indicates the size of terminal screw for R/L1, S/L2, T/L3, U, V, W, PR, P/+, N/-, P1, P3, and the screw for earthing
(grounding), and P/+ for option connection. A screw for earthing (grounding) of the FR-F860-02890 or higher is indicated in ( ).
Tightening
Crimping terminal
torque
N•m
R/L1,
U, V, W
S/L2,
T/L3
1.5
2-4
2-4
1.5
2-4
2-4
2.5
5.5-5
5.5-5
4.4
14-6
14-6
7.8
22-8
22-8
7.8
38-8
38-8
26.5
60-10
60-10
26.5
60-10
60-10
26.5
80-10
80-10
46
100-12
100-12
46
125-12
125-12
46
2×80-12 2×80-12 2×80-12 60-10
Tightening
Crimping terminal
torque
N•m
R/L1,
U, V, W
S/L2,
T/L3
1.5
2-4
2-4
1.5
2-4
2-4
2.5
5.5-5
5.5-5
4.4
14-6
14-6
7.8
22-8
22-8
7.8
38-8
38-8
26.5
60-10
60-10
26.5
60-10
60-10
26.5
80-10
80-10
46
100-12
100-12
46
125-12
125-12
46
2×80-12 2×80-12 2×80-12 60-10
P/+,
Earthing
R/L1,
P1
(grounding)
S/L2,
cable
T/L3
2-4
2-4
2
2-4
2-4
2
8-5
5.5-5
5.5
14-6
14-6
14
22-8
22-8
22
38-8
22-8
38
60-10
38-10
60
60-10
38-10
60
80-10
38-10
80
100-12
38-10
100
125-12
38-10
125
2×80
P/+,
Earthing
R/L1,
P1
(grounding)
S/L2,
cable
T/L3
2-4
2-4
14
2-4
2-4
14
8-5
5.5-5
10
14-6
14-6
6
22-8
22-8
4
38-8
22-8
1
60-10
38-10
1/0
60-10
38-10
2/0
80-10
38-10
4/0
100-12
38-10
250
125-12
38-10
2×2/0
2×4/0
*1
Cable gauge
2
HIV cables, etc. (mm
)
U, V,
P/+,
Earthing
W
P1
(grounding)
cable
2
2
2
2
2
2
5.5
8
5.5
14
14
14
22
22
22
38
38
22
60
60
38
60
60
38
80
80
38
100
100
38
125
125
38
2×80
2×80
60
*1
Cable gauge
AWG/MCM
U, V,
P/+,
Earthing
W
P1
(grounding)
cable
14
14
14
14
14
14
10
8
10
6
4
6
4
2
4
1
1/0
4
1/0
1/0
1
2/0
2/0
1
250
4/0
1
300
250
1
2×2/0
2×2/0
1
2×250
2×4/0
1/0
2. INSTALLATION AND WIRING
2.5 Main circuit terminals
3
2
3
4
5
6
7
8
9
10
45

Advertisement

Table of Contents
loading

Table of Contents