Mitsubishi Electric 800 Series Instruction Manual page 54

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

 Common terminal
Terminal
Common
Symbol
SD
Contact input common
(sink)
External transistor
common (source)
24 VDC power supply
common
PC
External transistor
common (sink)
Contact input common
(source)
SD
24 VDC power supply
5
Frequency setting
common
SE
Open collector output
common
*1
Source logic is initially set.
 Communication
Type
Terminal
Terminal name
symbol
PU connector
TXD+
Inverter transmission terminal
TXD-
RXD+
Inverter reception terminal
RXD-
GND
Earthing (grounding)
(SG)
USB A connector
USB B connector
 Terminals for manufacturer setting
Terminal symbol
S1
The terminals S1, S2, SIC, So (SO), and SOC are for manufacturer setting. Do not connect anything to these. Doing
so may cause an inverter failure.
S2
Do not remove the shorting wires across the terminals S1 and PC, the terminals S2 and PC, and the terminals SIC
SIC
and SD. Removing either shorting wire disables the inverter operation.
So (SO)
SOC
Terminal name
Common terminal for the contact input terminal (sink
logic)
Connect this terminal to the power supply common
terminal of a transistor output (open collector output)
*1
device, such as a programmable controller, in the
source logic to avoid malfunction by undesirable
current.
Common terminal for the 24 VDC power supply
(terminal PC, terminal +24).
Isolated from terminals 5 and SE.
Connect this terminal to the power supply common
terminal of a transistor output (open collector output)
device, such as a programmable controller, in the sink
logic to avoid malfunction by undesirable currents.
Common terminal for contact input terminal (source
*1
logic).
Can be used as a 24 VDC 0.1 A power supply.
Common terminal for frequency setting signal
(terminal 2, 1 or 4) and analog output terminal AM,
CA. Do not earth (ground).
Common terminal for terminals RUN, SU, OL, IPF, FU —
With the PU connector, communication can be made through RS-485. (For
connection on a 1:1 basis only)
Conforming standard: EIA-485 (RS-485)
Transmission format: Multidrop link
Communication speed: 4800 to 115200 bps
Wiring length: 500 m
The RS-485 terminals enables the communication by RS-485.
Conforming standard: EIA-485 (RS-485)
Transmission format: Multidrop link
Communication speed: 300 to 115200 bps
Overall length: 500 m
A connector (receptacle)
A USB memory device enables parameter
copies and the trace function.
Mini B connector (receptacle).
By connecting the inverter to a personal
computer via this connector, FR
Configurator2 installed on the computer can
be used for setting the inverter, or monitoring
or testing the inverter operation.
Terminal function description
Terminal function description
Terminal function description
Rated
Refer
specification
to
page
Power supply
55
voltage range
19.2 to 28.8 VDC
Permissible load
current 100 mA
318
Refer
page
473
475
Interface: Conforms to USB
67
1.1 (USB 2.0 full-speed
compatible)
Transmission speed:
67
12 Mbps
2. INSTALLATION AND WIRING
2.6 Control circuit
3
2
3
4
5
6
7
8
to
9
10
53