Mitsubishi Electric 800 Series Instruction Manual page 497

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Item
Set frequency (RAM)
Set frequency
(RAM, EEPROM)
Inverter reset
Fault history clear
Parameter clear
All clear
Parameter
Link parameter
Extended setting
Second parameter
changing (instruction
code HFF = 1, 9)
Multi command
Inverter
Inverter
model
model
monitor
Capacity
*1
Refer to
page 486
*2
Turning OFF the power supply while clearing parameters with H5A5A or H55AA returns the communication parameter settings to the initial
settings.
*3
Refer to the calibration parameter list below for details on calibration parameters.
*4
The gain frequency can be also written using Pr.125 (instruction code: H99) or Pr.126 (instruction code: H9A).
496
5. PARAMETERS
5.12 (N) Operation via communication and its settings
Read/
Instruction
Write
code
Write
HED
Write the set frequency/speed into the RAM or EEPROM.
H0000 to HE678 (0 to 590.00Hz): frequency in 0.01Hz increments
(The display can be changed to the rotations per minute using Pr.37 and
HEE
Pr.144. (Refer to
• To change the set frequency consecutively, write data to the inverter
RAM. (Instruction code: HED)
Write
HFD
H9696: Inverter reset
• As the inverter is reset at the start of communication by the computer,
the inverter cannot send reply data back to the computer.
H9966: Inverter reset
• After the computer correctly starts communication and send data to
the inverter, the inverter returns the ACK signal to the computer before
being reset.
Write
HF4
H9696: Fault history is cleared.
Write
HFC
All parameters return to initial values.
Whether to clear communication parameters or not can be selected
according to the data.
• Parameter clear
H9696: Parameters including communication parameters are cleared.
H5A5A: Parameters other than communication parameters are cleared.
• All parameter clear
H9966: Parameters including communication parameters are cleared.
H55AA: Parameters other than communication parameters are cleared.
For details on whether or not to clear parameters, refer to
When a clear is performed with H9696 or H9966, communication related
parameter settings also return to the initial values. When resuming the
operation, set the parameters again.
Performing a clear will clear the instruction code HEC, HF3, and HFF
settings.
Only H9966 and H55AA (all parameter clear) are valid during the
password lock (refer to
Read
H00 to H6B
Refer to the instruction code
values as required.
When setting Pr.100 and later, the link parameter extended setting must
Write
H80 to HEB
be set.
Read
H7F
Parameter settings are changed (extended) according to the settings.
For details of the settings, refer to the instruction code
Write
HFF
Read
H6C
When setting the calibration parameters
H00: Frequency
H01: Parameter-set analog value
H02: Analog value input from terminal
Write
HEC
Write/
HF0
Available for writing 2 commands, and monitoring 2 items for reading data
Read
(refer to
Read
H7C
Reading inverter model in ASCII code.
"H20" (blank code) is set for blank area
Example of "FR-F860-3"
H46, H52, H2D, H46, H38, H36, H30, H2D, H33, H20, H20.........H20
Read
H7D
The capacity in the inverter model can be read in ASCII code.
Data is read in increments of 0.1 kW, and rounds down to 0.01 kW
increments
"H20" (blank code) is set for blank area
Example
0.75K..."7" (H20, H20, H20, H20, H20, H37)
for data formats (A, A1, A2, B, C, C1, D, E, E1, E2, E3, F)
Data description
page
272))
page
170).
(page
623) and write and/or read parameter
*4
page 499
for detail)
*2
*2
page
623.
(page
623).
*3
Number of
data digits
*1
(Format)
4 digits (A and
C/D)
4 digits (A and
C/D)
4 digits (A and
D)
4 digits (A and
C/D)
4 digits (A and
C/D)
4 digits (B and
E/D)
4 digits (A and
C/D)
2 digits (B and
E1/D)
2 digits (A1
and C/D)
2 digits (B and
E1/D)
2 digits (A1
and C/D)
10 digits (A2
and C1/D)
20 digits (B
and E3/D)
6 digits (B and
E2/D)