Function
Pr.
PU
145
─
147
Current
148
detection
149
150
151
152
153
─
154
─
155
─
156
─
157
─
158
─
159
─
160
─
161
Automatic
162
restart
functions
163
164
165
Current
166
detection
167
─
168
─
169
Cumulative
170
monitor
171
114
5. PARAMETERS
5.1 Parameter List
Pr.
Name
group
E103
PU display language
selection
F022
Acceleration/
deceleration time
switching frequency
H620
Stall prevention level at 0
V input
H621
Stall prevention level at
10 V input
M460
Output current detection
level
M461
Output current detection
signal delay time
M462
Zero current detection
level
M463
Zero current detection
time
H631
Voltage reduction
selection during stall
prevention operation
T730
RT signal function
validity condition
selection
H501
Stall prevention
operation selection
M430
OL signal output timer
M301
AM terminal function
selection
A005
Automatic switchover
frequency range from
bypass to inverter
operation
E440
User group read
Simple
Simple
Simple
selection
E200
Parameter for manufacturer setting. Do not set.
A700
Automatic restart after
instantaneous power
failure selection
A704
First cushion time for
restart
A705
First cushion voltage for
restart
A710
Stall prevention
operation level for
restart
M433
Output current detection
signal retention time
M464
Output current detection
operation selection
E000
Parameter for manufacturer setting. Do not set.
E080
E001
E081
M020
Watt-hour meter clear
M030
Operation hour meter
clear
Setting range
Minimum
setting
increments
0 to 7
1
0 to 590 Hz, 9999
0.01 Hz
0 to 400%
0.1%
0 to 400%
0.1%
0 to 400%
0.1%
0 to 300 s
0.1 s
0 to 400%
0.1%
0 to 300 s
0.01 s
0, 1, 10, 11
1
0, 10
1
0 to 31, 100, 101
1
0 to 25 s, 9999
0.1 s
1 to 3, 5 to 14, 17, 18,
1
21, 24, 34, 50, 52 to
54, 61, 62, 67, 69, 70,
86 to 96, 98
0 to 10 Hz, 9999
0.01 Hz
0, 1, 9999
1
0 to 3, 10 to 13, 1000
1
to 1003, 1010 to 1013
0 to 20 s
0.1 s
0 to 100%
0.1%
0 to 400%
0.1%
0 to 10 s, 9999
0.1 s
0, 1, 10, 11
1
0, 10, 9999
1
0, 9999
1
Initial value
Refer
Customer
to
setting
page
─
165
9999
190
110%
257
120%
257
110%
307
0 s
307
5%
307
0.5 s
307
1
257
0
348
0
257
0 s
257
1
284
9999
376
9999
0
177
0
448,
454
0 s
448
0%
448
110%
448
0.1 s
307
0
307
9999
274
9999
274