Operation location
selection
Selectable
Pr.178
function
to
Pr.189
setting
*1
When Pr.77 = "2", Pr.162 setting can be changed during operation. The new setting is applied after stop. Until the inverter has stopped, the
previous setting of the interface for the operation command and the speed command in the Network operation mode is valid.
220
5. PARAMETERS
5.6 (D) Operation command and frequency command
Pr.338 Communication operation
command source
Pr.339 Communication speed
command source
39
PDI2
PID multistage set point setting
2
40
PDI3
PID multistage set point setting
3
46
TRG
Trace trigger input
47
TRC
Trace sampling start/end
48
X48
Power failure stop external
50
SQ
Sequence start
51
X51
Fault clear
57
JOGF
JOG forward rotation command ―
58
JOGR
JOG reverse rotation command ―
60
STF
Forward rotation command
61
STR
Reverse rotation command
62
RES
Inverter reset
64
X64
During retry
65
X65
PU/NET operation switchover
66
X66
External/NET operation
switchover
67
X67
Command source switchover
70
X70
DC feeding operation
permission
71
X71
DC feeding cancel
72
X72
PID P control switchover
73
X73
Second PID P control
switchover
77
X77
Pre-charge end command
78
X78
Second pre-charge end
command
79
X79
Second PID forward/reverse
action switchover
80
X80
Second PID control valid
terminal
81
PGT
PID gain tuning start/forced end NET External
84
X84
Emergency drive execution
command
92
X92
Emergency stop
94
X94
Control signal input for main
circuit power supply MC
95
X95
Converter unit fault input
96
X96
Converter unit fault (E.OHT,
E.CPU) input
97
X97
Cleaning valid
98
X98
Cleaning trigger
128
RLF
Low-speed forward rotation
command
129
RLR
Low-speed reverse rotation
command
0: NET
1: EXT
0:
1: EXT
2:
0:
NET
EXT
NET
NET External
NET
NET External
NET
Combined
External
Combined
External
External
External, NET
External
Combined
External
External
External
NET
External
NET
External
External
NET External
NET
External
External
External
NET
External
NET
External
NET External
NET
NET External
NET
NET External
NET
NET External
NET
NET External
NET
NET External
NET
NET
Combined
External
External
External
External
NET
External
NET
External
Remarks
1:
2:
EXT
EXT
External
External
Pr.414= "1": Valid
when there is
external or network
input
Pr.414= "2":
External
External
External
External
External
External
External
External
External
External
External

Advertisement