 PID monitor indicator setting (Pr.999 = "1 or 2")
Pr.
759
PID unit selection
1142
Second PID unit selection
774
Operation panel monitor selection 1
775
Operation panel monitor selection 2
776
Operation panel monitor selection 3
934
PID display bias coefficient
935
PID display gain coefficient
1136
Second PID display bias coefficient
1138
Second PID display gain coefficient
3-step monitor setting
Direct setting
Dedicated parameter list function
*1
Enabled when the FR-LU08 (-01) is used.
*2
Enabled when the FR-PU07 is used.
*3
Enabled when the FR-PU07-01 is used.
 3-line monitor setting
On the operation panel or parameter unit, the 3-line monitor is used as the first monitor.
 Direct setting
Pressing the [FUNC] key of the FR-PU07-01 displays the direct setting screen. The PID action set point can be directly set
regardless of the operation mode or Pr.77 Parameter write selection setting.
Pressing the [FUNC] key on the direct setting screen displays the function menu.
Direct setting
Direct setting 1
Direct setting 2
 Dedicated parameter list function
Pressing the [PrSET] key of the FR-PU07-01 displays the dedicated parameter list. Parameters that need to be set first for the
PID extended display setting are listed.
Dedicated parameter list
No.1
No.2
No.3
NOTE
• The display of parameters other than the above may be changed due to changes in Pr.934 or Pr.935. Set the PID monitor
indicator before changing the settings of other parameters.
• To use the direct setting on the LCD operation panel, set Pr.1000 Direct setting selection. (Refer to
174
5. PARAMETERS
5.4 (E) Environment setting parameters
Name
Initial value
9999
9999
9999
9999
9999
9999
9999
9999
9999
Parameter to be set
Pr.133 PID action set point
Pr.755 Second PID action set point
Parameter to be set
Pr.999 Automatic parameter setting
Pr.934 PID display bias coefficient
Pr.935 PID display gain coefficient
Pr.999="1"
Pr.999="2"
9999
4
9999
4
9999
52
9999
53
9999
54
9999
0
9999
100
9999
0
9999
100
Disabled
*1*2*3
Enabled
Disabled
*3
Enabled
Disabled
*3
Enabled
Refer to page
421
274
421
page
166.)