Safety Observation; Safety Observation Screen (Configuration Diagnosis) - Mitsubishi Electric C80 Series Instruction Manual

Hide thumbs Also See for C80 Series:
Table of Contents

Advertisement

C80 Series Instruction Manual
10 Troubleshooting

10.5 Safety Observation

Diagn
Safety
The configuration, signal status, drive status and version in use of the smart safety observation function are displayed on
the safety observation screen.

10.5.1 Safety Observation Screen (Configuration Diagnosis)

The available/unavailable states of the smart safety observation function are displayed on the configuration diagnosis
screen.
(1)
(2)
(3)
Display items
Display items
(1)
Active function
(2)
NC-DRV safety communi-
cation
The drive safety functions which are enabled with the parameters are highlighted.
SIO: Safety-related I/O observation, emergency stop observation
SLS: Safety-limited speed observation
SLP: Safety-limited position observation
SSM: Safe speed monitor
SCA: Safe cam
SOS: Safe operating stop observation
SS1: Safe stop 1
SS2: Safe stop 2
STO: Safe torque OFF
SBC: Safe brake control
This displays the safety communication status of the drive unit.
To perform the safety drive communication, the smart safety observation target
axis needs to be set by the parameter, and the connected channel with the drive
unit needs to be optical communication and configured only with drive units MDS-
E Series.
Valid prm ax:
Out of the axes connected to each channel, the axes that the parameter "#51101
SF_Disable" (Disable smart safety observation) is OFF are highlighted. For the
axis with safety detector, "*" appears at the top of the axis name.
383
Details
IB-1501453-C

Advertisement

Table of Contents
loading

Table of Contents