Mitsubishi Electric C80 Series Instruction Manual page 238

Hide thumbs Also See for C80 Series:
Table of Contents

Advertisement

C80 Series Instruction Manual
5 Setting a Tool and a Workpiece
(8)
<Measurement using touch probe>
Make the spindle contact the workpiece using manu-
al feed or manual handle feed.
<Without the touch probe (simple measurement)>
Move the spindle to the arbitrary position and press
the menu [SkipPos take in].
(9)
Measure points B and C in the same way.
(10) Select the workpiece coordinate system offset in
which the measurement data will be set.
(Example) To select G55
Press the menus [Coord G54-G59] [G55].
(11) Press the menu [Coord write].
(12) Return the tool to the reference position, and turn the
measurement switch OFF.
Upon contact, the skip position displays in the measure-
ment counter point A.
The cursor moves to point B. For point C, the cursor
moves to point A.
The skip position is calculated and the results appear in
the measurement counter point A.
The cursor moves to point B. For point C, the cursor
moves to point A.
The hole center position is measured.
Based on the parameter "#8709 Ext work sign rvs" set-
ting, the value achieved by adding or subtracting the ex-
ternal workpiece offset to or from the measurement
result is set in workpiece coordinate system selected at
(10).
The parameters "#8623 Coord rot centr(H)", "#8624 Co-
ord rot centr(V)", and "#8627 Coord rot angle" are updat-
ed.
The measurement counter displays blank.
213
IB-1501453-C

Advertisement

Table of Contents
loading

Table of Contents