Workpiece Measurement (L System) - Mitsubishi Electric C80 Series Instruction Manual

Hide thumbs Also See for C80 Series:
Table of Contents

Advertisement

C80 Series Instruction Manual
5 Setting a Tool and a Workpiece

5.7.2 Workpiece Measurement (L System)

The external workpiece coordinate offset data for the Z axis can be set by cutting the workpiece face by means of manual
operations and inputting the workpiece measurement signal. By pressing the menu key, data can be set in the Z axis of an
arbitrary coordinate offset.
Coordinate offset setting for the Z axis (2nd axis) of the part system 1 to 4 is possible.
Note that the workpiece coordinate offsets for multiple part systems cannot be measured at the same time.
For signals and R registers, refer to the instruction manual issued by the MTB.
Note
(1) Measurement is disabled for the part system with one-axis structure.
Example of measurement of external workpiece coordinate offset data for Z axis
(1)
(2)
(3)
(4)
Manual numerical value command can be executed when manual numerical value command window is displayed by input-
ting an address key such as MST, etc.
X axis
Workpiece
215
Machine
Tool post
zero point
Z axis
Workpiece coordinate
zero point
(5)
(6)
IB-1501453-C