5 Setting a Tool and a Workpiece
Operation method ("0.012" is calculated and set in the length wear data for compensation number (102).)
(1)
Use the same procedure as in the previous page to
move the cursor to the compensation No. 102 length
wear position.
(2)
Input a numeric value.
0.012 [+INPUT]
Note
(1) If the parameter "#11017 T-ofs set at run" is set to "1", the tool compensation amount data during automatic operation
or during pause of operation can be set.
(2) This setting may be disabled due to the parameter "#8933 Disable lngth comp" or "8934 Disable wear comp" setting.
For details, refer to "5.4.6 Disabling the Setting of Tool Compensation Amount".
(3) When [=Input], [+Input] and [Input] are pressed and when the parameter "#1124 ofsfix" is set to "0", the cursor will move
to the next compensation No.
(4) When entering data without decimal points, you can select the 1-mm (or 1-inch) data input or the input in the minimum
input unit (same as "#1003 iunit") by designating the "#8119 Comp. unit switch" parameter.
<1-mm unit: "#8119 Comp. unit switch" is "0".>
Input
1
100
10.
.012
<Minimum input unit (#1003 iunit B): "#8119 Comp. unit switch" is "1".>
Input
1
100
10.
.012
IB-1501453-C
The input value added to the original value is displayed.
(Example) If the original data is 10.000:
Result
1.000
100.000
10.000
0.012
Result
0.001
0.100
10.000
0.012
150
10.000 + 0.012 = 10.012 is displayed.