5 Setting a Tool and a Workpiece
Display items
Display items
(1)
On mea
(2)
Measure posn
(3)
Prg zero offset (L)
"On mea" is displayed when the measurement switch is ON.
<Note>
This is displayed only in "Manual tool length measurement II".
When "Manual tool length measurement I" is performed, the measurement result and
measurement axis are displayed.
<Normal operation mode>
Measurement result is displayed by pressing the menu [Meas memory] when the
cursor is placed at the axis to be measured.
Measurement Position: Machine position when the menu operation is performed.
<Simple operation mode>
Measurement result for the axis selected using either the menu [Measure X] or the
axis address key.
Measurement Position: Machine position when the menu operation or address key
operation is performed.
<Note>
This is displayed only in "Manual tool length measurement I".
The data of maximum 3 axes displays when "Manual tool length measurement I
(Simple operation mode)" is selected.
The axis names set in the parameter "#1022 axname2" are displayed.
Workpiece measurement result is set and displayed.
Setting range: -99999.999 to 99999.999 (mm)
<Normal operation mode>
Setting is possible by pressing the menu [Zero-ptoffset] or touching the value area of
the "Prg zero offset (L)".
<Simple operation mode>
Select the axis to measure using either the menu [Measure X] or the axis address
key. Then the cursor moves to "Prg zero offset (L)", where setting a measured value
is enabled.
<Note>
The data of maximum 3 axes displays when "Manual tool length measurement I
(Simple operation mode)" is selected.