Ethernet Connection - Mitsubishi Electric GT1685 Connection Manual

Got1000 series
Table of Contents

Advertisement

18.2.4 Ethernet connection

MELDAS
C6/C64
CNC
Model name
Expansion unit
FUC6-EX875
MELDAS C6/C64
*4*5
*1
The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.
Connect to the Ethernet module, hub, transceiver or other system equipment corresponding to the applicable Ethernet network
system.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standards.
A cross cable is available for connecting the GOT to the Ethernet module.
*2
When connecting GT16 of the function version A to an equipment that meets the 10BASE (-T/2/5) standard, use the switching
hub and operate in a 10Mbps/100Mbps mixed environment.
For how to check the function version, refer to the following.
*3
A length between a hub and a node.
The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of
cascades.
For the limit, contact the switching hub manufacturer.
*4
For the system configuration of the expansion unit, refer to the following manuals.
*5
Select [AJ71QE71] for [Controller Type] in [Ethernet] of GT Designer3.
For [Ethernet] of GT Designer3, refer to the following.
18 - 6
18. CNC CONNECTION
18.2 System Configuration
Expansion
unit
Connection cable
Communication
Cable model
type
Twisted pair cable
• 10BASE-T
Shielded twisted pair cable
(STP) or unshielded twisted
pair cable (UTP): Category
Ethernet
3, 4, and 5
• 100BASE-TX
Shielded twisted pair cable
(STP):
Category 5 and 5e
GT16 User's Manual
C6/C64/C64T CONNECTION AND MAINTENANCE MANUAL BNP-B2255
C6/C64/C64T NETWORK INSTRUCTION MANUAL BNP-B2373
18.4.3 Ethernet setting
GOT
*1
Connection cable
Maximum
segment
*3
length
100m
Communication driver
Ethernet(MELSEC),Q17nNC,CRnD-700
GOT
Option device
Model
*2
- (Built into GOT)
GT15-J71E71-100
Number of
connectable
equipment
128 GOTs
(recommended to
16 units or less)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents