13.4.7 Connecting to CC-Link module
(Q Series) with Ver.1/Ver.2
compatibles mixed
This section describes the setting of the GOT and CC-Link
module (Q Series) with Ver.1/Ver.2 compatibles mixed in
the following system configuration.
POINT
POINT
POINT
CC-Link module (Q Series)
For details of the CC-Link module (Q Series), refer to
the following manual.
CC-Link System Master/Local Module User's
Manual QJ61BT11N
System configuration
■ [Controller Setting] of GT Designer3
■ Setting of the CC-Link communication unit
<GOT (Ver.1 compatible)>
(Use default value for settings other than the following.)
Station type
Station No.
Number of stations
occupied
Transmission speed
*1
<CC-Link module>
(Use default value for settings other than the following.)
Type
: Master station
Station No.
: Station No. 0
Mode
: Remote net (Ver.2 mode)
All connect count
: 2
Transmission speed : 156kbps
■ Switch setting of CC-Link module (Q Series)
■ [Network parameter] of GX Developer
*1
The CC-Link module is mounted on the base unit slot 0.
The Start I/O No. of the CC-Link module is set to "0"
POINT
POINT
POINT
When connecting to Q170MCPU
When connected to Q170MCPU, the start I/O No. of
the CC-Link module is set to "70".
: Intelligent device
station
: Station No. 1
:
Exclusive station 1
:
156kbps
<GOT (Ver.2 compatible)>
(Use default value for settings other
than the following.)
Station type
: Intelligent device
station
Station No.
: Station No. 2
Expanded cyclic setting
:
Single
Number of stations
:
Exclusive station 1
occupied
Transmission speed
:
156kbps
13. CC-Link CONNECTION (INTELLIGENT DEVICE STATION)
Switch setting of CC-Link module (Q Series)
Set the station number setting switch, transmission
speed / mode setting switch.
QJ61BT11N
QJ61BT11N
RUN
L RUN
MST
S MST
SD
RD
ERR.
L ERR.
STATION
NO.
X10
X1
C
MODE
NC
NC
2
DA
SLD
4
DB
(FG)
6
DG
(1) Station number setting switch
Station number
Description
setting switch
Station number
setting
(master station)
: Necessary
(2) Transmission rate/mode setting switch
Transmission
rate/mode setting
Description
switch
Transmission
rate/
mode setting
(Online:
*1
156kbps)
: Necessary
*1
Specify the same transmission speed as that of the GOT.
POINT
POINT
POINT
When the switch setting has been changed
Turn the PLC CPU OFF then ON again, or reset the
PLC CPU.
13.4 PLC Side Setting
(1)
(2)
1
3
5
7
Setting necessity
Set value
at GOT connection
0 (fixed)
: As necessary
: Not necessary
Setting necessity
Set value
at GOT connection
0
: As necessary
: Not necessary
13 - 29
9
10
11
12
13
14
15
16

Hide quick links: