Mitsubishi Electric GT1685 Connection Manual page 640

Got1000 series
Table of Contents

Advertisement

(4) CC-Link Ver.2 (ID)
Item
Description
Set the station No. of the GOT.
Station No.
(Default: 1)
Set the transmission speed and
Transmission
the mode of the GOT.
*1
Rate
(Default: 0)
Set the mode of CC-Link.
Mode
(Default: Ver.1)
Expanded
Set the cyclic point expansion.
Cyclic
(Default: Single)
Set the number of stations
Occupied
occupied by the GOT.
Station
(Default: 1 Station)
Set Clear/Hold at an error
Input for Error
occurrence.
Station
(Default: Clear)
Set the number of retries to be
performed when a communication
timeout occurs.
Retry
When no response is received
after retries, a communication
times out.
(Default: 3times)
Set the time period for a
Timeout Time
communication to time out.
(Default: 3sec)
Set the delay time for reducing the
load of the network/destination
Delay Time
PLC.
(Default: 0ms)
*1
Transmission speed settings
The following lists the transmission speed settings of the CC-
Link communication.
Set value
0
1
2
3
4
A
B
C
D
E
For details of the hardware test, refer to the following
manual.
CC-Link System Master/Local Module User's
Manual for CC-Link module to be used
18 - 10
18. CNC CONNECTION
18.4 GOT Side Settings
Range
1 to 64
0 to E
Ver.1/Ver.2/
Additional/
Offline
Single/
Double/
Quadruple/
Octuple
1 Station/4 Stations
Clear/Hold
0 to 5times
3 to 90sec
0 to 300ms
Description
Online: 156kbps
Online: 625kbps
Online: 2.5Mbps
Online: 5Mbps
Online: 10Mbps
Hardware test: 156kbps
Hardware test: 625kbps
Hardware test: 2.5Mbps
Hardware test: 5Mbps
Hardware test: 10Mbps
(5) CC-Link(ID)
Item
Description
Set the number of retries to be
performed when a communication
timeout occurs.
Retry
When receiving no response after
retries, the communication times out.
(Default: 3times)
Set the time period for a communication
Timeout Time
to time out.
(Default: 3sec)
Range
0 to 5times
3 to 90sec