Connecting To Cc-Link Module (A Series) - Mitsubishi Electric GT1685 Connection Manual

Got1000 series
Table of Contents

Advertisement

[Controller Setting] of GT Designer3
(1) When MODEL GT15-J61BT13 CC-Link
communication unit is used
Item
Station No.
Transmission Rate
Mode
Expanded Cyclic
Number of stations occupied
Input for Error Station
Retry
Timeout Time
Delay Time
(2) When MODEL GT15-75J61BT13-Z CC-Link
communication unit is used
Item
Retry
Timeout Time
POINT
POINT
POINT
[Controller Setting] of GT Designer3
For the setting method of [Controller Setting] of GT
Designer3, refer to the following.
13.3.1 Setting communication interface
(Communication settings)
Setting of the CC-Link communication unit
(Only when MODEL GT15-75J61BT13-Z
CC-Link communication unit is used)
Item
Mode setting switch
Station number setting switch
Transmission baudrate setting switch
SW1
(Input data status of the data
Condition
link error station)
setting
switches
SW2 (Number of occupied
stations)
POINT
POINT
POINT
Setting of the CC-Link communication unit
For the setting method of the CC-Link communication
unit, refer to the following.
13.3.3 Switch setting (Only when MODEL
GT15-75J61BT13-Z CC-Link communication
unit is used)
13 - 40
13. CC-Link CONNECTION (INTELLIGENT DEVICE STATION)
13.4 PLC Side Setting
Set value
1: Station No.1
0: Online 156kbps
Ver.1: Remote net (Ver.1 mode)
Single (Use default value)
1 Station
0: Clear
3times (Use default value)
3sec (Use default value)
0ms (Use default value)
Set value (Use default value)
3times
3sec
Set value
0: Online (fixed)
1: Station No.1
0: 156kbps
OFF: Cleared
OFF: 1 station
13.4.11 Connecting to CC-Link module
(A Series)
This section describes the settings of the GOT and CC-
Link module (A Series) in the following case of system
configuration.
POINT
POINT
POINT
CC-Link module (A Series)
For details of the CC-Link module (A Series), refer to
the following manual.
Control & Communication Link System Master/
Local Module Type AJ61BT11/A1SJ61BT11
User's Manual
System configuration
■ [Controller Setting] of GT Designer3
■ Setting of the CC-Link communication unit
<CC-Link module>
*1
(Use the default value for settings other than the following.)
Station type
: Master station
Station No.
: Station No.0
Mode setting
: Remote net mode
: 1
All connect count
Transmission speed : 156kbps
Module mode
: Intelligent mode
■ Settings of CC-Link module (A Series)
■ Sequence program
*1
The CC-Link module is mounted on the base unit slot 0.
The Start I/O No. of the CC-Link module is set to "0"
<GOT>
(Use the default value for settings other
than the following.)
: Intelligent device
Station type
station
Station No.
: Station No.1
Number of station occupied : Exclusive station 1
Transmission
: 156kbps
speed