Routing Parameter Setting - Mitsubishi Electric GT1685 Connection Manual

Got1000 series
Table of Contents

Advertisement

Item
Description
Set the number of refreshes to
secure the send/receive data in
station units during
communication.
Refresh
(Default: 1time)
Interval
Valid when "Secured data send/
Secured data receive" is marked
by the control station side network
parameters of the MELSECNET/H
network system.
Set the communication
transmission speed.
Transmission
(Default: 25Mbps)
Speed
When specifying [MNET/10 mode]
as the network type, only 10Mbps
can be set applicable.
*1
Cannot be set for the QCPU redundant system.
*2
For details, refer to the following manual.
Q corresponding MELSECNET/H Network System
Reference Manual (PLC to PLC network)
(2) MELSECNET/10
Item
Description
Set the number of retries to be
performed when a communication
timeout occurs.
Retry
When no response is received after
retries, a communication times out.
(Default: 3times)
Set the time period for a communication
Timeout Time
to time out.
(Default: 3sec)
POINT
POINT
POINT
(1) When MELSECNET/H communication unit is used
When connecting the MELSECNET/H network
module to the MELSECNET/10 network system,
specify the [MNET/10 mode] as a [Network Type].
(2) Communication interface setting by the Utility
The communication interface setting can be
changed on the Utility's [Communication Settings]
after writing [Communication Settings] of project
data.
For details on the Utility, refer to the following
manual.
GT
User's Manual
(3) Precedence in communication settings
When settings are made by GT Designer3 or the
Utility, the latest setting is effective.
Range

10.3.3 Routing parameter setting

Up to 64 [Transfer Network No.]s can be set.
However, the same transfer network number cannot be set
1 to 1000times
twice or more (multiple times).
Therefore, the one that can access to other station from the
request source host GOT is 64 kinds of [Transfer Network
No.]s.
POINT
POINT
POINT
10Mbps/25Mbps
Range
0 to 5times
3 to 90sec
Transfer Network No.
Relay Network No.
Relay Station No.
POINT
POINT
POINT
10. MELSECNET/10 CONNECTION (PLC TO PLC NETWORK)
(1) Routing parameter setting
When communicating within the host network,
routing parameter setting is unnecessary.
(2) Selection of communication unit
Routing parameters cannot be set in the GT15-
75J71LP23-Z and the GT15-75J71BR13-Z.
When setting routing parameters, use the GT15-
J71LP23-25 or the GT15-J71BR13 according to
the connection type to be used.
For details of routing parameters, refer to the following
manual.
Q corresponding MELSECNET/H Network
System Reference Manual (PLC to PLC
network)
Item
1 to 239
1 to 239
1 to 64
Routing parameter setting of relay station
Routing parameter setting is also necessary for the
relay station.
For the setting, refer to the following.
10.4 PLC Side Setting
10.3 GOT Side Settings
9
10
11
12
13
14
Range
15
16
10 - 11