Got1000 series
Table of Contents

Advertisement

(2) Open settings
The setting is required for all the connected GOTs.
Item
Protocol
Open system
Host station port No.
8 - 34
8. ETHERNET CONNECTION
8.4 PLC Side Setting
Set value
UDP (fixed)
MELSOFT connection (fixed)
(Use default value)
[Controller Setting] and [Ethernet] of GT
Designer3
POINT
POINT
POINT
(3) [Controller Setting] and [Ethernet] of GT
Designer3
For [Controller Setting] and [Ethernet] of GT
Designer3, refer to the following.
8.3.1 Setting communication interface
(Communication settings)
(4) Ethernet setting
When connecting Built-in Ethernet port CPU to a
GOT, the settings items for the network No. and
station No. do not exist at the PLC side. However,
these virtual values must be set on the GOT side.
Therefore, set the network No. and station No.
Set the network No. that is not existed on the
network system and any station No..
(1) Controller setting
Item
GOT NET No.
GOT PLC No.
GOT IP Address
GOT Port No. (Communication)
GOT Port No.
(Ethernet Download)
Default Gateway
Subnet Mask
Retry
Startup Time
Timeout Time
Delay Time
(2) Ethernet setting
Item
Host
N/W No.
PLC No.
Ethernet setting
Type
No.1
IP address
Port No.
Communication
*1
Set the same value as that of GOT N/W No.
*2
Set a value different from that of the GOT PLC No. and the
PLC No. of other PLCs on the same network.
Set value (Use default value)
1
1
192.168.0.18
5001
5014
0.0.0.0
255.255.255.0
3times
3sec
3sec
0ms
Set value
*
-
*1
*1
1
1
*2
*2
2
3
QnUDE(H),
QnUDE(H),
LCPU
LCPU
192.168.0.1
192.168.0.2
5006 (fixed)
5006 (fixed)
UDP (fixed)
UDP (fixed)