*2
Set only when selecting "AJ71E71" in [Controller Type].
When other than [AJ71E71] is selected, the port No. is as
follows.
• [RCPU], [RnCCPU], [QnUDE(H)]: 5006 (fixed)
• [FX5CPU]: 5562 (fixed)
• [RJ71EN71][Q17nNC], [QJ71E71], [AJ71QE71]: 5001
(fixed)
• [FX]: 5551 (When using FX
5556 (When using FX
When using built-in Ethernet port FXCPU:5556
*3
When selecting the FX in [Controller Type], the
communication type is the TCP (fixed).
*4
Each of [GOT PLC No.] set in the communication detail
setting and [PLC No.] set in the Ethernet setting must be set
to different station numbers.
8.3.2 Communication detail settings
POINT
POINT
POINT
(1) Example of [Ethernet setting]
For examples of [Ethernet setting], refer to the
following.
8.4 PLC Side Setting
(2) Parameter reflection function of MELSOFT
Navigator
(a) The color of the cells for the items which are
reflected to GT Designer3 from MELSOFT
Navigator changes to green. Set items, which
are displayed in green cells, from the
MELSOFT Navigator.
(b) When the settings of N/W No., PLC No., type
or IP address are reflected to the parameter
from the MELSOFT Navigator, those settings
are added. Items set in advance are not
deleted. However, if the combination of the N/
W No. and the PLC No. or the IP address
overlaps, the item set in advance is
overwritten.
(3) Changing the host on the GOT main unit
The host can be changed by the utility function of
the GOT main unit. For the detailed connection
method, refer to the following manual.
User's Manual of GOT used.
(When using GT16)
8 - 20
8. ETHERNET CONNECTION
8.3 GOT Side Settings
-ENET-L)
3U
-ENET-ADP)
3U
8.3.4
Routing parameter setting
Up to 64 [Transfer Network No.]s can be set.
However, the same transfer network number cannot be set
twice or more (multiple times).
Therefore, the one that can access to other station from the
request source host GOT is 64 kinds of [Transfer Network
No.]s.
POINT
POINT
POINT
Routing parameter setting
When communicating within the host network, routing
parameter setting is unnecessary.
For details of routing parameters, refer to the following
manual.
Q Corresponding Ethernet Interface Module
User's Manual (Application)
Item
Transfer Network No.
*1
Relay Network No.
*1
Relay Station No.
*1
When accessing to other networks relaying a Build-in
Ethernet port CPU, set the virtual network No. and PLC No.
set in the Ethernet settings on GT Designer3.
Range
1 to 239
1 to 239
1 to 64