Accessing By Setting/ Monitoring Tool For C Controller Module - Mitsubishi Electric GT1685 Connection Manual

Got1000 series
Table of Contents

Advertisement

23.6.18 Accessing by Setting/ Monitoring
tool for C Controller module
The following shows the procedure to set the FA
transparent function of Setting/Monitoring tool for C
Controller module with the C Controller module (Q Series)
(Q24DHCCPU-V) connected.
When connecting the GOT and personal
computer with USB
(1) When connecting the GOT and PLC in bus
connection
1.
Click the Connection Destination view
[Connection Destination]
data name)] in the Navigation window of MT Setting/
Monitoring tool for C Controller module.
2.
The [Transfer Setup] is displayed.
3.
Set the [Transfer Setup]:
PLC side I/F : GOT
Other station : No specification
4.
Double-click [GOT] of the CPU side I/F to display
[CPU side I/F Detailed Setting of GOT].
[(Connection target
5.
Mark the [via GOT(Bus) transparent mode]
checkbox on the [CPU side I/F Detailed Setting of
GOT] screen.
6.
The screen returns to [Transfer Setup]. Click
[Connection Test] to check if Setting/Monitoring tool
for C Controller module has been connected to the
motion controller (Q mode).
(2) When connecting the GOT and PLC in Ethernet
communication
1.
Click the Connection Destination view
[Connection Destination]
data name)] in the Navigation window of MT Setting/
Monitoring tool for C Controller module.
2.
The [Transfer Setup] is displayed.
3.
Set the [Transfer Setup]:
PLC side I/F : GOT
Other station : No specification
23. FA TRANSPARENT FUNCTION
23.6 Personal Computer Side Setting
[(Connection target
23 - 79
17
18
19
20
21
22
23