When connecting the GOT and PC with Ethernet (For GT16, GT15, GT14, GT12)
PLC
Varies according to
the connection type.
PLC
Connection type
For the system configuration
between the GOT and PLC,
refer to the following.
COMPUTER LINK
CONNECTION
For the system configuration
between the GOT and PLC,
refer to the following.
CC-Link IE
CONTROLLER NETWORK
CONNECTION
For the system configuration
between
the GOT and PLC, refer to
the following.
BUS
*4
CONNECTION
DIRECT
*6
CONNECTION TO CPU
COMPUTER LINK
*6
CONNECTION
*1
The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.
Connect to the Ethernet module, hub, transceiver, or other system equipment corresponding to the applicable Ethernet network
system.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standards.
A cross cable is available for connecting the GOT to the Ethernet module.
*2
When connecting GT16 of the function version A to an equipment that meets the 10BASE (-T/2/5) standard, use the switching
hub and operate in a 10Mbps/100Mbps mixed environment.
For how to check the function version, refer to the following.
*3
A length between a hub and a node.
The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of
cascades.
For the limit, contact the switching hub manufacturer.
*4
LCPU is not applicable to the bus connection.
*5
GT14 models compatible with Ethernet connection are only GT1455-QTBDE, GT1450-QMBDE and GT1450-QLBDE.
*6
Not applicable to Setting/Monitoring tool for C Controller module.
23 - 36
23. FA TRANSPARENT FUNCTION
23.4 System Configuration
GOT
Connection cable
GOT
Model
Interface
*2
*5
- (Built into GOT)
*2
- (Built into GOT)
*2
*5
- (Built into GOT)
GT15-J71E71-100
GT16 User's Manual
PC
*1
Connection cable
Cable model
Twisted pair cable
• 10BASE-T
Shielded twisted pair cable
(STP) or unshielded
twisted pair cable (UTP):
Category 3, 4, and 5
• 100BASE-TX
Shielded twisted pair cable
(STP):
Category 5 and 5e
Communication driver
Connection type
dependant
Personal
Maximum
computer
segment
*3
length
Software
GX Works3
MX
Component
computer for 1 GOT
MX Sheet
GX Works2
computer for 1 GOT
100m
GX Works2
Setting/
Monitoring tool
for C Controller
module
Number of
connectable
equipment
1 personal
1 personal
1 personal
computer
for 1 GOT