Connecting To Melsec-Q/L - Mitsubishi Electric GT1685 Connection Manual

Got1000 series
Table of Contents

Advertisement

11.4.3

Connecting to MELSEC-Q/L

 System configuration1
(Network Type: CC IE Control)
■ GT Designer3 [Communication settings] of System
configuration1 (Network Type: CC IE Control)
<GOT>
(Use the default value for settings other
than the following.)
CC-Link IE Controller Network
<CC-Link IE Controller Network module> *
(Use the default value for settings other than the following.)
Station No.
Mode
Network type
Network No.
Total stations
Network range assignment :
■ [Network parameter] of GX Developer
*1
The CC-Link IE Controller Network module is mounted on
slot 0 of the base unit.
The start I/O No. of the CC-Link IE Controller Network
module is set at [0].
POINT
POINT
POINT
When connecting to Q170MCPU
When connected to Q170MCPU, the start I/O No. of
the CC-Link IE Controller Network module is set to
"70".
 System configuration2
(Network Type: CC IE Control extended mode)
<GOT>
(Use the default value for settings other
than the following.)
CC-Link IE Controller Network
<CC-Link IE Controller Network module> *
(Use the default value for settings other than the following.)
Station No.
Mode
Network type
Network No.
Total stations
Network range assignment :
*1
The CC-Link IE Controller Network module is mounted on
slot 0 of the base unit.
The start I/O No. of the CC-Link IE Controller Network
module is set at [0].
LB0100
to LB01FF
H
H
LW00100
to LW001FF
H
H
1
: 1
: Online
: CC IE Control (Control station)
: 1
: 2
LB0000
to LB00FF
H
H
LW00000
to LW000FF
H
H
LB0100
to LB01FF
H
H
LW00100
to LW001FF
H
H
1
: 1
: Online
: CC IE Control extended mode
(Control station)
: 1
LB0000
to LB00FF
: 2
H
H
LW00000
to LW000FF
H
H
11. CC-Link IE CONTROLLER NETWORK CONNECTION
 Parameter settings (Connection to MELSEC-
Q, QS series) of System configuration1
(Network Type: CC IE Control)
(1) [Network parameter] of GX Developer
(a) Network parameter
Item
Network type
(Control station) (fixed)
*1
Starting I/O No.
*2
Network No.
Total stations
Group No.
Station No.
*3
Mode
Network range assignment
Refresh parameters
Interrupt settings
(Use default value)
Interlink transmission
parameters
Routing parameters
: Necessary
*1
When using Q170MCPU, set it according to the system
configuration.
*2
Specify the same network No. as that of the GOT.
*3
Set the same mode setting as that of the GOT.
11.4 PLC Side Setting
Setting
necessity at
Set value
GOT
connection
CC IE Control
0000
H
1
2
0 (fixed)
1
Online
Refer to (b)
Refer to (c)
: As necessary
: Not necessary
11 - 19
9
10
11
12
13
14
15
16