(2) Assignment contents of the PLC side word device
The following table shows the device assignment
contents when setting [Head Device (10 Points)] to
"D0".
Device
D0 (Head device+0)
D1(Head device+1)
D2(Head device+2)
D3(Head device+3)
D4(Head device+4)
D5(Head device+5)
D6(Head device+6)
D7(Head device+7)
D8(Head device+8)
D9(Head device+9)
(3) Details on the word device assignment contents
(a) Control signal 1-1
Bit position
bit0
10 second cycle flicker signal
bit1 to 15
(Reserve)
< 10 second cycle flicker signal
By the repetition of turning ON/OFF every 5
seconds, the connection between GT01-RS4-M
and the PLC can be confirmed on the PLC side.
When no repetition of this ON/OFF is observed,
GT01-RS4-M is not connected to the PLC.
5sec
ON
OFF
*1
When writing or clearing data on the program area from the
personal computer to the PLC using FA transparent function,
flicker of the signal as shown above may be temporarily
stopped.
(b) Station information notification signal
This signal notifies the status of the slave station
(GOT) which is connected to the master station
(GT01-RS4-M). Only the bit corresponding to the
number of connected slave station (GOT) is turned
ON and other bits are turned OFF.
bit15
bit14
Station
Station
No. 15
No. 14
• 1: Connected
• 0: Unconnected (Including communication error
status)
*2
When the communication between GT01-RS4-M and the
PLC becomes faulty, the station information notification
signal is not updated.
20 - 28
20. GOT MULTI-DROP CONNECTION
20.6 Setting of Serial Multi-Drop Connection Unit
Description
Control signal 1-1
Station information notification signal
(Reserve)
(Reserve)
(Reserve)
Slave station control signal
(Reserve)
(Reserve)
(Reserve)
(Reserve)
Description
*1
>
5sec
*2
..................
bit2
bit1
Station
Station
..................
No. 2
No. 1
(c) Slave station control signal
This signal controls slave stations which are not
updated by the master station.
Usually, the master station accesses all stations
(up to 16 stations). In addition, if stations are
temporarily in communication error due to a power
disconnection or screen data transfer during the
steady operation, the automatic recovery of the
station is executed for one station per ten seconds.
Therefore, the automatic recovery may take
maximum 2 minutes and 30 seconds.
Using this control signal, the number of slave
stations to be monitored by the master station can
be reduced to the actual number of slave stations
to be used by a user. This makes the automatic
recovery processing smooth. If an error occurs in
only one station, the time for the station to recover
automatically can be reduced within 10 seconds.
Device
value
0
Other
than 0
When the bits are off and the master station and
the slave stations are in communication, the
communication with the corresponding slave
stations is disconnected if the above corresponding
bits are turned on.
bit0
Station
No. 0
Action
The master station accesses all the slave stations
(station 0 to 15). When the multi-drop system
information is not used, the operation is the same.
Turning on the bit corresponding to a station No.
disconnects the specified slave station from the
master station.
bit15
bit14
..........
bit2
Station
Station
Station
..........
No. 15
No. 14
No. 2
1...Connected
0...Unconnected
bit1
bit0
Station
Station
No. 1
No. 0