10.4.3 Connecting to MELSECNET/
10 network module (A Series)
This section describes the settings of the GOT and
MELSECNET/10 network module (A Series) in the
following case of system configuration.
In this section, the network parameter (common
parameter) of GX Developer is taken as an example to
provide explanations.
POINT
POINT
POINT
MELSECNET/10 network module (A Series)
For details of the MELSECNET/10 network module (A
Series), refer to the following manual.
Type MELSECNET/10 Network system (PLC to
PLC network) Reference Manual
System configuration
■ [Controller Setting] of GT Designer3
■ Setting of the MELSECNET/10 communication unit
<GOT>
(Use the default value for settings other
MELSECNET/10 (PLC to PLC network)
<MELSECNET/10 network module> *1
(Use the default value for settings other than the following.)
Station No.
Mode
Network type
Network No.
Total stations
Network range assignment: LB0000
■ Switch setting of MELSECNET/10 network module
■ [Network parameter] of GX Developer
*1
The MELSECNET/10 network module is mounted at slot 0 of
the base unit.
The start I/O No. of the MELSECNET/10 network module is
set at "0".
10 - 22
10. MELSECNET/10 CONNECTION (PLC TO PLC NETWORK)
10.4 PLC Side Setting
than the following.)
: 1
: Online
: MNET/10 (Control station)
: 1
: 2
to LB00FF
H
H
LW0000
to LW00FF
H
H
Switch setting of MELSECNET/10 network
module
Set for each setting switch.
AJ71LP21
A
J71LP21
RUN -
- POWER
PC -
- MNG
10
REMOTE -
- S.MNG
1
DUAL -
- D.LINK
SW.E -
- T.PASS
100
M/S.E -
- EX.POWER
PRM.E -
- CPUR/W
CRC -
- C RC
OVER -
- OVER
E
E
E
AB.IF -
- AB.IF
R
R
R
TIME -
- TIME
R
R
R
DATA -
- DATA
UNDER -
- UNDER
O
O
O
R
LOOP -
- LOOP
R
R
SD -
- SD
RD -
- RD
F.LOOP
R.LOOP
NETWORK NO.
X100
X10
X1
GROUP NO.
STATION NO.
X10
X1
MODE
0: ONLINE(A.R)
2: OFFLINE
OFF
ON
OFF
ON SW
PC
REMOTE
1
N.ST
MNG
2
3
PRM
D.PRM
STATION SIZE
4
(8.16.32.64)
5
6
LB/ LW SIZE
(2.4.6.8K)
7
8
FRONT SIDE
IN
OUT
A1SJ71LP21
A1SJ71LP21
RUN
PW
CRC
E
MNG
PC
OVER
R
S.MNG
REM.
AB. IF
R
DUAL
SWE.
TIME
O
D.LINK
M/S.E.
DATA
R
T.PAS.
PRM E.
UNDER
F.E.
R.E.
SD
CPU R/W
RD
NETWORK
NO.
DISPLAY
X100
L
R
(F.L)
(R.L.)
(1)
X10
X1
SW
OFF
ON
1
PC
REM.
2
N.ST
MNG
(2)
3
PRM
D.PRM
GR.NO.
4
ST,SIZE
5
8,16,32,64
ST.NO.
6
LB/LW SIZE
X10
7
2,4,6,8k
(3)
8
X1
OFF ON
SW
C
1
(5)
MODE
2
3
MODE
4
0 : ONLINE(A,R)
5
2 : OFFLINE
6
FRONT SIDE
7
8
IN
OUT
A1SJ71LP21
AJ71BR11
A
J71BR11
RUN -
- POWER
PC -
- MNG
REMOTE -
- S.MNG
10
1
- D.LINK
SW.E -
- T.PASS
-
M/S.E -
100
PRM.E -
- CPUR/W
CRC -
OVER -
E
AB.IF -
R
TIME -
R
DATA -
UNDER -
O
R
SD -
RD -
NETWORK NO.
X100
(1)
X10
X1
(2)
GROUP NO.
STATION NO.
X10
(3)
X1
(5)
MODE
0: ONLINE(A.R)
2: OFFLINE
OFF
ON
OFF
ON SW
PC
REMOTE
1
N.ST
MNG
2
PRM
D.PRM
3
(6)
STATION SIZE
4
(8.16.32.64)
5
LB/LW SIZE
6
(2.4.6.8K)
7
8
A1SJ71BR11
A1SJ71BR11
RUN
PW
CRC
E
MNG
PC
OVER
R
S.MNG
REM.
AB. IF
R
SWE.
TIME
O
D.LINK
M/S.E.
DATA
R
T.PAS.
PRM E.
UNDER
SD
CPU R/W
RD
NETWORK
NO.
DISPLAY
(4)
X100
L
R
(1)
X10
X1
SW
OFF
ON
1
PC
REM.
2
N.ST
MNG
(2)
3
PRM
D.PRM
GR.NO.
4
ST,SIZE
5
8,16,32,64
ST.NO.
6
LB/LW SIZE
X10
7
2,4,6,8k
(3)
8
X1
OFF ON
SW
C
(5)
1
MODE
2
3
(6)
MODE
4
0 : ONLINE(A,R)
5
2 : OFFLINE
6
7
8
A1SJ71BR11
(1)
(2)
(3)
(5)
(6)
(4)
(6)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents