(4) When connecting the GOT and PLC in Ethernet communication
The following shows the software and the accessible PLC CPUs.
PLC CPU
RCPU
Motion controller CPU (MELSEC iQ-R Series)
C Controller module (MELSEC iQ-R Series)
FX5U, FX5UC
*1
QCPU (Q mode)
, C Controller module (Q Series)
LCPU
FXCPU
*1
QCPU (A mode), QnA/ACPU
Motion controller CPU (Q Series)
CNC CPU(Q173NCCPU)
Robot controller (CRnQ-700, CRnD-700)
*17
MELSERVO(MR-J3-B)
*17
MELSERVO(MR-J4-B)
*1
Only QCPU can be connected.To connect to QnA/ACPU, connect via QCPU.
*2
GX Developer Version 8.78G or later is required to use the FA transparent function.
*3
MELSOFT Navigator Version 1.04E or later is required to use the FA transparent function.
*4
GX Works2 Version 1.10L or later is required to use the FA transparent function.
*5
MT Works2 Version 1.08J or later is required to use the FA transparent function.
*6
NC Configurator Version A1 or later is required to use the FA transparent function.
*7
GX Developer Version 8.88S or later is required to use the FA transparent function.
*8
GX Works2 Version 1.11M or later is required to use the FA transparent function.
*9
MT Works2 Version 1.12N or later is required to connect with Q17nDCPU-S1.
*10
MELSOFT Navigator Version 1.07H or later is required to use the FA transparent function.
*11
MX Component Version 4.03D or later is required to use the FA transparent function.
*12
Use MX Component Version 3.14Q or later for MX Sheet.
*13
GX Works2 Version 1.34L or later is required to execute the FA transparent function with using CC-Link IE Field Network Ethernet
adapter (NZ2GF-ETB).
C controller module (Q Series) does not support CC-Link IE Field Network.
*14
CPU Module Logging Configuration Tool Version 1.04E or later is required to use the FA transparent function.
*15
RT ToolBox2 Version 1.7 or later is required to use the FA transparent function.
*16
MR Configurator2 Version 1.09K or later is required to use the FA transparent function.
*17
A motion controller is required between the GOT and PLC in Ethernet connection.
*18
Setting/Monitoring tool for C Controller module Version 4.00A or later is required to use the FA transparent function.
*19
GX Works2 Version 1.98C or later is required to use the FA transparent function.
*20
MT Works2 Version 1.100E or later is required to use the FA transparent function.
*21
MX Component Version 4.06G or later is required to use the FA transparent function.
*22
Use MX Component Version 4.06G or later for MX Sheet.
*23
GX Works3 Version 1.005F or later is required to use the FA transparent function.
*24
MX Component Version 4.11M or later is required to use the FA transparent function.
*25
MX Sheet, please use the MX Component (Version 4.11M or later).
*21
GX Works3, MX Component
, MX Sheet
*20
*21
MT Works2
, MX Component
, MX Sheet
CW Configurator
*23
GX Works3
,
MX Component
*3
MELSOFT Navigator
*2
GX Developer
*4*13
GX Works2
*11
*12
MX Component
,
MX Sheet
Setting/Monitoring tool for C Controller module
*10
MELSOFT Navigator
*7
GX Developer
*8
GX Works2
GX LogViewer
*11
*12
MX Component
,
MX Sheet
,
*19
GX Works2
*2
GX Developer
*11
*12
MX Component
,
MX Sheet
*3
MELSOFT Navigator
*5*9
MT Works2
*6
NC Configurator
*15
RT ToolBox2
MR Configurator2
*16
MR Configurator2