13.3 GOT Side Settings

13.3.1 Setting communication
interface (Communication
settings)
Set the channel of the connected equipment.
2.
1.
Select [Common]
[Controller Setting] from the
menu.
2.
The Controller Setting window is displayed. Select the
channel to be used from the list menu.
3.
Set the following items.
• Manufacturer: MITSUBISHI ELECTRIC
• Controller Type: Set according to the Controller
Type to be connected.
• I/F: Interface to be used
• Driver:
When MODEL GT15-J61BT13 CC-Link
communication unit is used
CC-Link Ver2 (ID)
When MODEL GT15-75J61BT13-Z CC-Link
communication unit is used
CC-Link (ID)
4.
The detailed setting is displayed after Manufacturer,
Controller Type, I/F, and Driver are set.
Make the settings according to the usage
environment.

13.3.2 Communication detail settings

Click the [OK] button when settings are completed.
POINT
POINT
POINT
The settings of connecting equipment can be
confirmed in [I/F Communication Setting].
For details, refer to the following.
13.3.2 Communication detail settings
3.
Make the settings according to the usage environment.
(1) CC-Link Ver.2 (ID)
4.
Click!
Item
Station No.
Transmission
*1
Rate
Mode
Expanded
Cyclic
Occupied
Station
Input for Error
Station
Retry
Timeout Time
Delay Time
13. CC-Link CONNECTION (INTELLIGENT DEVICE STATION)
1.1.2 I/F communication setting
Description
Set the station No. of the GOT.
(Default: 1)
Set the transmission speed and
the mode of the GOT.
(Default: 0)
Set the mode of CC-Link.
(Default: Ver.1)
Set the cyclic point expansion.
(Default: Single)
Set the number of stations
occupied by the GOT.
(Default: 1 Station)
Set Clear/Hold at an error
occurrence.
(Default: Clear)
Set the number of retries to be
performed when a communication
timeout occurs.
When no response is received
after retries, a communication
times out.
(Default: 3times)
Set the time period for a
communication to time out.
(Default: 3sec)
Set the delay time for reducing the
load of the network/destination
PLC.
(Default: 0ms)
13.3 GOT Side Settings
9
10
11
12
13
Range
1 to 64
0 to E
Ver.1/Ver.2/
14
Additional/Offline
Single/Double/
Quadruple/Octuple
1 Station/4 Stations
Clear/Hold
15
0 to 5times
16
3 to 90sec
0 to 300 (ms)
13 - 11