Mitsubishi Electric GT1685 Connection Manual page 103

Got1000 series
Table of Contents

Advertisement

2.4 MELSEC-L
The device ranges that can be set when selecting
[MELSEC-L] as the controller type are as follows.
Device name
Input (X)
X0
Output (Y)
Y0
*5
M0
Internal relay (M)
Latch relay (L)
L0
Annunciator (F)
F0
Link relay (B)
B0
Contact (TT)
TT0
*5
Timer
Coil (TC)
TC0
Contact (CT)
CT0
*5
Counter
Coil (CC)
CC0
Special relay (SM)
SM0
Retentive
Contact (SS)
SS0
*5
timer
Coil (SC)
SC0
Step relay (S)
S0
Link special relay (SB)
SB0
The bit specification of the
word device
Setting range of each
(except Timer, Counter,
Retentive timer, Index
register)
*5
D0
Data register (D)
Special data register (SD)
SD0
Link register (W)
W0
*5
TN0
Timer (current value) (TN)
Counter (current value)
CN0
*5
(CN)
Retentive timer
SN0
*5
(current value) (SN)
Link special register (SW)
SW0
*1*2
R0
File register (R)
Extension file register
ZR0
*1*3
(ZR)
Index register (Z)
Z0
Buffer memory
(Intelligent function module)
BM0
*4
(BM)
Buffer memory
(Intelligent function module)
G0
*4
(G)
*6*7
Ww0 to
Ww
*6*7
Wr0
Wr
The word specification of
*6*8
Setting range of each bit
the bit device
(except Timer, Counter,
Retentive timer)
Device No.
Setting range
representation
to
X3FFF
Hexadecimal
to
Y3FFF
to
M61439
Decimal
to
L32767
to
F32767
to
BEFFF
Hexadecimal
to
TT32767
to
TC32767
to
CT32767
to
CC32767
Decimal
to
SM2047
to
SS32767
to
SC32767
to
S8191
to
SB7FFF
Hexadecimal
word device
to
D421887
Decimal
to
SD2047
to
W66FFF
Hexadecimal
to
TN32767
to
CN32767
Decimal
to
SN32767
to
SW7FFF
Hexadecimal
to
R32767
to
ZR393215
to
Z19
Decimal
to
BM32767
to
G65535
Ww1FFF
Hexadecimal
to
Wr1FFF
devices
*1
Do not set a file register by GT Designer3 when executing
multiple programs with the file of the file register set at [Use
the same file name as the program] by the PLC parameter of
GX Developer.
Otherwise, read/write at GOT will be erroneous.
*2
Available for file register of block No. switched with the RSET
instruction.
*3
Available for file register of block No. of file name switched
with the QDRSET instruction.
*4
Only the intelligent function module on the station connected
to GOT can be specified.
Set within the address range of the buffer memory existing in
the target intelligent function module.
*5
Do not use local devices set in the MELSEC-L system.
Otherwise, normal monitoring is not performed. (The data
register (D) can be used for D32768 or later.)
*6
This is not supported by GT10.
*7
This cannot be monitored when in GOT multi-drop
connection.
*8
The device No. must be set in multiples of 16.
2. DEVICE RANGE THAT CAN BE SET
2.4 MELSEC-L
1
2
3
4
5
6
7
8
2 - 11