5.3 GOT Side Settings
5.3.1
Setting communication
interface (Communication
settings)
Set the channel of the connected equipment.
2.
1.
Select [Common]
menu.
2.
The Controller Setting window is displayed. Select the
channel to be used from the list menu.
3.
Set the following items.
• Manufacturer: MITSUBISHI ELECTRIC
• Controller Type: Set the option according to the
Controller Type to be connected.
• I/F: Interface to be used
• Driver: Set either of the following option according
to the Controller Type to be connected.
BUS (Q)
BUS (A/QnA)
4.
The detailed setting is displayed after Manufacturer,
Controller Type, I/F, and Driver are set.
Make the settings according to the usage
environment.
5.3.2 Communication detail settings
Click the [OK] button when settings are completed.
POINT
POINT
POINT
The settings of connecting equipment can be
confirmed in [I/F Communication Setting].
For details, refer to the following.
1.1.2 I/F communication setting
5 - 32
5. BUS CONNECTION
5.3 GOT Side Settings
3.
4.
Click!
[Controller Setting] from the
5.3.2
Communication detail settings
(1) Bus(Q)
Item
Description
Number of
(Default: 1)
Stages
Slot No.
(Default: 0)
Set the monitor speed of the GOT.
Monitor Speed
This setting is not valid in all systems.
(Default: Normal)
Set the time period for a
Timeout Time
communication to time out.
(Sec.)
(Default: 12)
*1
This range is effective when collecting a large amount of
data (such as logging and recipe function) on other than the
monitor screen.
However, the range may affect the sequence scan time
when connecting to Q00UJ/Q00U/Q01U/Q02UCPU or Q00J/
Q00/Q01CPU.
If you want to avoid the influence on the sequence scan time,
do not set [High].
(This setting hardly affects QCPUs other than the above.)
*2
Set this range if you want to avoid the influence on the
sequence scan time further than the [Normal] setting when
connecting to Q00UJ/Q00U/Q01U/Q02UCPU or Q00J/Q00/
Q01CPU.
However, the monitor speed may be reduced.
(2) Bus(A/QnA)
Item
Description
Number of
(Default: 1)
Stages
Slot No.
(Default: 0)
Set the time period for a
Timeout Time
communication to time out.
(Sec.)
(Default: 3)
Range
1 to 7
0 to 9
*1
High
/Normal/
*2
Low
12 to 90
Range
1 to 7
0 to 7
3 to 90