Mitsubishi Electric GT1685 Connection Manual page 772

Got1000 series
Table of Contents

Advertisement

*13
GX Developer Version 8.88S or later is required to use the FA transparent function.
*14
GX Works2 Version 1.11M or later is required to use the FA transparent function.
*15
The adapter (L6ADP-R2 or L6ADP-R4) is required.
*16
MELSOFT Navigator Version 1.07H or later is required to use the FA transparent function.
*17
MX Component Version 4.03D or later is required to use the FA transparent function.
*18
Use MX Component Version 3.14Q or later for MX Sheet.
*19
Start MR Configurator2 with MT Developer2 Version 1.10L or later.
*20
CPU Module Logging Configuration Tool Version 1.04E or later is required to use the FA transparent function.
*21
MR Configurator2 Version 1.09K or later is required to use the FA transparent function.
*22
A motion controller is required between the GOT and PLC in direct CPU connection.
*23
MX Component Version 4.00A or later is required to use the FA transparent function.
*24
MX Component Version 4.00A or later is required for MX Sheet to use the FA transparent function.
*25
FR Configurator Version5.21 or later is required to use the FA transparent function.
*26
GX Works3 Version 1.005F or later is required to use the FA transparent function.
*27
MX Component Version 4.11M or later is required to use the FA transparent function.
*28
MX Sheet, please use the MX Component (Version 4.11M or later).
(3) When connecting the GOT and PLC in computer link connection
The following shows the software and the accessible PLC CPUs.
PLC CPU
RCPU
QCPU (Q mode)
LCPU
*1
GX Developer Version 8.62Q or later is required to use the FA transparent function.
GX Developer Version 8.68W or later is required to use the FA transparent function when connecting the QnUDE(H)CPU to the
GOT.
*2
PX Developer Version 1.18U or later is required to use the FA transparent function.
*3
GX Configurator-QP Version2.32J or later is required to use the FA transparent function.
*4
MELSOFT Navigator Version 1.04E or later is required to use the FA transparent function.
*5
GX Works2 Version 1.03D or later is required to use the FA transparent function.
*6
GX Developer Version 8.88S or later is required to use the FA transparent function.
*7
GX Works2 Version 1.11M or later is required to use the FA transparent function.
*8
MELSOFT Navigator Version 1.07H or later is required to use the FA transparent function.
*9
MX Component Version 4.03D or later is required to use the FA transparent function.
*10
Use MX Component Version 3.14Q or later for MX Sheet.
*11
CPU Module Logging Configuration Tool Version 1.04E or later is required to use the FA transparent function.
*12
MX Component Version 4.06G or later is required to use the FA transparent function.
*13
Use MX Component Version 4.06G or later for MX Sheet.
23 - 10
23. FA TRANSPARENT FUNCTION
23.2 Compatible Software
*12
GX Works3, MX Component
, MX Sheet
*4
MELSOFT Navigator
*1
GX Developer
*5
GX Works2
*2
PX Developer
*3
GX Configurator-QP
*9
MX Component
,
MX Sheet
*8
MELSOFT Navigator
*6
GX Developer
*7
GX Works2
GX LogViewer
*9
MX Component
,
MX Sheet
Software
*13
*10
*10
,
CPU Module Logging Configuration Tool
*11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents