[Network parameter] of GX Developer
(1) Network parameter
Item
No. of boards in module
*1
Start I/O No.
Operation setting
(Use default value)
Type
Master station (fixed)
Mode
All connect count
Remote input (RX)
Remote output (RY)
Remote register (RWr)
Remote register (RWw)
Special relay (SB)
Special register (SW)
Retry count
Automatic reconnection
station count
Stand by master station No.
(Use default value)
PLC down select
Scan mode setting
Delay information setting
Station information setting
Remote device station initial
setting
(Use default value)
Interrupt setting
: Necessary
*1
Set the Start I/O No. of the CC-Link module according to the
system configuration.
Setting
necessity at
Set value
GOT
connection
1
0000
H
Remote net
(Ver.2 mode)
1
X400
Y400
D300
D200
SB0
SW0
Refer to (2)
: As necessary
: Not necessary
13. CC-Link CONNECTION (INTELLIGENT DEVICE STATION)
(2) Station information setting
*1
Item
Ver.2 intelligent device
Station type
*2
Expanded cyclic setting
*2
Exclusive station count
Remote station points
Reserve/invalid station select
Intelligent buffer select (word)
(Use default value)
: Necessary
*1
When the [Mode] of the CC-Link module is set at [Remote
net - (Ver. 2 mode)], [Remote station points] can be set.
[Remote station points] is a setting for the remote I/O station.
The default value (32 points) must be used on the GOT.
*2
Set the same setting as that of the GOT.
POINT
POINT
POINT
When changing the network parameter
After writing the network parameter to the PLC CPU,
operate the PLC CPU either turning OFF and then ON
or resetting.
[Controller Setting] of GT Designer3
Item
Station No.
Transmission Rate
Mode
Expanded Cyclic
Number of stations occupied
Input for Error Station
Retry
Timeout Time
Delay Time
POINT
POINT
POINT
[Controller Setting] of GT Designer3
For the setting method of [Controller Setting] of GT
Designer3, refer to the following.
13.3.1 Setting communication interface
(Communication settings)
13.4 PLC Side Setting
Setting
necessity at
Set value
GOT
connection
station (fixed)
Single
Exclusive station 1
32 points (fixed)
No setting
: As necessary
: Not necessary
Set value
1: Station No.1
0: Online 156kbps
Ver.2: Remote net (Ver.2 mode)
Single
1 Station
0: Clear
3times (Use default value)
3sec (Use default value)
0ms (Use default value)
13 - 35
9
10
11
12
13
14
15
16