(b) A1SJ71UC24-R2, A1SJ71UC24-PRF,
A1SJ71C24-R2, A1SJ71C24-PRF
Transmission
Setting
specifications
switch
switch
SW03
Unused
SW
ON
Write during RUN
SW04
enabled/disabled setting
03
04
SW05
Transmission speed
ON
SW06
setting
05
SW07
06
SW08
Data bit setting
07
08
SW09
Parity bit setting
09
SW10
Even/odd parity setting
10
11
SW11
Stop bit setting
12
SW12
Sum check setting
• Transmission speed setting (SW05 to SW07)
Set the transmission speed (SW05 to SW07) as
follows.
The transmission speed setting must be consistent
with that of the GOT side.
Transmission speed
Setting switch
4800bps
SW05
OFF
SW06
OFF
SW07
ON
*1
Only transmission speeds available on the GOT side are
shown.
(c) A1SJ71UC24-R4, A1SJ71C24-R4
Transmission
Setting
specifications
switch
switch
Master station/Local
SW01
station setting
Computer link/multi-drop
SW02
selection
ON
SW
01
SW03
Unused
02
Write during RUN
03
SW04
enabled/disabled setting
04
ON
SW05
05
Transmission speed
SW06
06
setting
07
SW07
08
SW08
Data bit setting
09
10
SW09
Parity bit setting
11
12
SW10
Even/odd parity setting
SW11
Stop bit setting
SW12
Sum check setting
Set
Description
value
OFF
Enabled
ON
(Consistent
See
with the GOT
descripti
side
ons
specifications)
below.
8bits
ON
Set
ON
Odd
OFF
1bit
OFF
Set
ON
*1
9600bps
19200bps
ON
OFF
OFF
ON
ON
ON
Set
Description
value
(Setting
OFF
ignored)
Computer
ON
link
OFF
Enabled
ON
(Consistent
See
with the GOT
descripti
side
ons
specifications)
below.
8bits
ON
Set
ON
Odd
OFF
1bit
OFF
Set
ON
• Transmission speed setting (SW05 to SW07)
Set the transmission speed (SW05 to SW07) as
follows.
The transmission speed setting must be consistent
with that of the GOT side.
Transmission speed
Setting switch
4800bps
SW05
OFF
SW06
OFF
SW07
ON
*1
Only transmission speeds available on the GOT side are
shown.
(d) A1SCPUC24-R2
Transmission
Setting
specifications
switch
switch
Write during RUN
1
enabled/
disabled setting
2
ON
Transmission speed
3
setting
4
5
Data bit setting
6
Parity bit setting
Even/odd parity
7
setting
8
Stop bit setting
9
Sum check setting
• Transmission speed setting (2 to 4)
Set the transmission speed (2 to 4) as follows.
The transmission speed setting must be consistent
with that of the GOT side.
Transmission speed
Setting switch
4800bps
2
OFF
3
OFF
4
ON
*2
Only transmission speeds available on the GOT side are
shown.
7. COMPUTER LINK CONNECTION
7.5 PLC Side Setting
*1
9600bps
19200bps
ON
OFF
OFF
ON
ON
ON
Description
Set value
Enabled
ON
(Consistent
with the
See
GOT side
description
specification
s below.
s)
8bits
ON
Set
ON
Odd
OFF
1bit
OFF
Set
ON
*2
9600bps
19200bps
ON
OFF
OFF
ON
ON
ON
7 - 29
1
2
3
4
5
6
7
8

Hide quick links: