Mitsubishi Electric GT1685 Connection Manual page 337

Got1000 series
Table of Contents

Advertisement

Ethernet parameter settings of FX
ADP
(1) Ethernet settings
Set the Ethernet parameter at [FX Parameter] on GX
Works2.
To set FX
-ENET-ADP, GX Works2 Ver.1.90U or later
3U
is required.
For details on the setting of FX
the following manual.
FX
-ENET-ADP User's Manual
3U
Item
Setting
Channel
CH1 or CH2
IP Address
192.168.1.250
Open Settings
Refer to (2).
Communication Data
Code
Disable direct
connection to
(Use default value.)
MELSOFT
Do not respond to
search for CPU on
network
:Required
*1
Set a channel according to the installation position of FX
ENET-ADP on the CPU body.
*2
The default value of IP address is 192.168.1.250. Set the IP
address corresponding to the system configuration.
POINT
POINT
POINT
When changing Ethernet parameter
After writing Ethernet parameters to the PLC CPU, turn
the PLC CPU OFF then back ON again.
-ENET-
3U
-ENET-ADP, refer to
3U
Setting
(with GOT connected)
*1
*2
:Set if necessary
:Not required
-
3U
(2) Open settings
Item
Setting
Protocol
TCP
Open System
MELSOFT connection
POINT
POINT
POINT
When connecting to multiple GOTs and peripheral
devices
The number of protocols equivalent to that of the GOTs
and devices must be set.
\
8. ETHERNET CONNECTION
8.4 PLC Side Setting
1
2
Setting
(with GOT connected)
3
4
5
6
7
8
8 - 51