Setting item
(For MELSEC-QnU/DC, Q17nD/M/NC/DR, CRnD-700)
(For MELSEC-FX)
Item
Set the device name, device number, and bit number.
The bit number can be set only by specifying the bit of word device.
When setting buffer memory (BM) and (G), set the buffer memory address in the space for the device number.
Block
Device
Intelligent
function
module
MELSEC-
FX buffer
memory
Information
Displays the device type and its setting range selected in [Device].
Set the station number of the controller to be monitored.
CPU No.
Host
Network
Other
Reading the device comment data created by GX Developer and confirming the device
comment/device name are available during device setting.
For details on the procedure to refer to the device comment, refer to the following.
GT Designer3 Version
Set the block number of the extended file register.
This item can be set only when the extended file register (ER) is selected.
Set when the buffer memory (BM) is selected.
Unit top I/O
Set the head I/O number of the buffer memory for the intelligent function module.
Set the first 2 digits of the 3-digit head I/O number.
Set when the buffer memory (G) is selected.
Unit No.
Set the head I/O number of the buffer memory for the intelligent function module.
Set the first 2 digits of the 3-digit head I/O number.
Set for using the buffer memory of MELSEC-FX series.
Set the mask type for monitoring or writing only specified bits of the buffer memory.
Mask type
(4) Setting of the mask type (MELSEC-FX)
Set for using the buffer memory of MELSEC-FX series.
Set the module No. of the special function unit or special function block to monitor or write.
Unit No.
(5) Setting of the module No. (MELSEC-FX)
Set the CPU No. of the controller.
(1) Setting of the CPU No.
Select this item for monitoring the host controller.
Select this for monitoring other controllers.
After selecting the item, set the station number and network number of the controller to be
monitored.
NW No.: Set the network No.
Station No.: Set the station No.
When selecting buffer memory (G) with the following controllers

MELSEC-QnU/DC, Q17nD/M/NC/DR, CRnD-700

MELSEC-L

MELSEC-QnA/Q/QS, MELDAS C6 *

MELSEC-Q(MULTI)/Q MOTION
Description
Screen Design Manual
2. DEVICE RANGE THAT CAN BE SET
1
2
3
4
5
6
7
8
2 - 3