Mitsubishi Electric GT1685 Connection Manual page 616

Got1000 series
Table of Contents

Advertisement

Device name
PD15 to PD16,
For manufacturer setting
PD1015 to PD1016
PD17, PD1017
Input device selection 8L
PD18, PD1018
Input device selection 8H
PD19, PD1019
Input device selection 9L
PD20, PD1020
Input device selection 9H
PD21, PD1021
Input device selection 10L
PD22, PD1022
Input device selection 10H
PD23, PD1023
Output device selection 1
PD24, PD1024
Output device selection 2
PD25, PD1025
Output device selection 3
PD26, PD1026
Output device selection 4
PD27, PD1027
For manufacturer setting
PD28, PD1028
Output device selection 6
PD29, PD1029
Response level setting
PD30, PD1030
Function selection D-1
PD31, PD1031
Function selection D-2
PD32, PD1032
Function selection D-3
PD33, PD1033
Function selection D-4
PD34, PD1034
Function selection D-5
PD35 to PD40,
For manufacturer setting
PD1035 to PD1040
Input signal automatic on
PD41, PD1041
selection 3
Input signal automatic on
PD42, PD1042
selection 4
PD43, PD1043
Input device selection 11L
PD44, PD1044
Input device selection 11H
PD45, PD1045
Input device selection 12L
PD46, PD1046
Input device selection 12H
PD47, PD1047
Output device selection 7
PD48, PD1048
For manufacturer setting
*1
For the parameters prefixed by an asterisk (*), setting
becomes effective when the power is turned off once and
back on after setting the parameter data.
(i) Extension setting No.2 parameter
Device name
Fully closed loop function
PE1, PE1001
selection 1
PE2, PE1002
For manufacturer setting
Fully closed loop function
PE3, PE1003
selection 2
Fully closed loop control -
PE4, PE1004
Feedback pulse electronic gear 1
- Numerator
Fully closed loop control -
PE5, PE1005
Feedback pulse electronic gear 1
- Denominator
Fully closed loop control - Speed
PE6, PE1006
deviation error detection level
Fully closed loop control -
PE7, PE1007
Position deviation error detection
level
Fully closed loop dual feedback
PE8, PE1008
filter
PE9, PE1009
For manufacturer setting
Fully closed loop function
PE10, PE1010
selection 3
PE11 to PE33,
For manufacturer setting
PE1011 to PE1033
16 - 52
16. SERVO AMPLIFIER CONNECTION
16.6 Device Range that Can Be Set
*1
Item
Symbol
*DI8L
*DI8H
*DI9L
*DI9H
*DI10L
*DI10H
*DO1
*DO2
*DO3
*DO4
*DO6
*DIF
*DOP1
*DOP2
*DOP3
*DOP4
*DOP5
*DIA3
*DIA4
*DI11L
*DI11H
*DI12L
*DI12H
*DO7
*1
Item
Symbol
*FCT1
*FCT2
*FBN
*FBD
BC1
BC2
DUF
FCT3
Device name
Fully closed loop control -
PE34, PE1034
Feedback pulse electronic gear 2
- Numerator
Fully closed loop control -
PE35, PE1035
Feedback pulse electronic gear 2
- Denominator
PE36 to PE40,
For manufacturer setting
PE1036 to PE1040
PE41, PE1041
Function selection E-3
PE42 to PE43,
For manufacturer setting
PE1042 to PE1043
Lost motion compensation
PE44, PE1044
positive-side compensation value
selection
Lost motion compensation
PE45, PE1045
negative-side compensation
value selection
PE46, PE1046
Lost motion filter setting
PE47, PE1047
Torque offset
Lost motion compensation
PE48, PE1048
function selection
PE49, PE1049
Lost motion compensation timing LMCD
Lost motion compensation non-
PE50, PE1050
sensitive band
PE51 to PE64,
For manufacturer setting
PE1051 to PE1064
*1
For the parameters prefixed by an asterisk (*), setting
becomes effective when the power is turned off once and
back on after setting the parameter data.
(j) Extension setting No.3 parameter
Device name
PF1 to 8,
For manufacturer setting
PF1001 to PF1008
PF9, PF1009
Function selection F-5
PF10 to PF14,
For manufacturer setting
PF1010 to PF1014
Electronic dynamic brake
PF15, PF1015
operating time
PF16 to PF20,
For manufacturer setting
PF1016 to PF1020
Drive recorder switching time
PF21, PF1021
setting
PF22, PF1022
For manufacturer setting
Vibration tough drive - Oscillation
PF23, PF1023
detection level
Vibration tough drive function
PF24, PF1024
selection
SEMI-F47 function -
PF25, PF1025
Instantaneous power failure
detection time
PF26 to PF30,
For manufacturer setting
PF1026 to PF1030
Machine diagnosis function -
PF31, PF1031
Friction judgement speed
PF32 to PF33,
For manufacturer setting
PF1032 to PF1033
RS-422 communication function
PF34, PF1034
selection 3
PF35 to PF48,
For manufacturer setting
PF1035 to PF1048
*1
For the parameters prefixed by an asterisk (*), setting
becomes effective when the power is turned off once and
back on after setting the parameter data.
*1
Item
Symbol
*FBN2
*FBD2
EOP3
LMCP
LMCN
LMFLT
TOF
*LMOP
LMCT
*1
Item
Symbol
*FOP5
DBT
DRT
OSCL1
OSCL2
CVAT
FRIC
*SOP3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents