ABB IRB 6640 - 180/2.55 Product Manual page 277

Articulated robot
Table of Contents

Advertisement

Replacement of SMB unit (Foundry Prime)
Robots working with Foundry Prime and that have the special tightness for this application
require special repair routines to maintain the tightness level.
The repair must be done according to the previous repair procedure with the following
additions.
3HAC026876-001 Revision: C
Action
4. Connect all connectors to the SMB board and fit
the SMB unit onto the pins.
5. Secure the SMB unit to the pins with the nuts and
washers.
6. If disconnected, reconnect the connectors X8, X9
and X10 to the brake release board.
7. Secure the SMB cover with its attachment
screws.
8. Update the revolution counter!
9.
DANGER!
Make sure all safety requirements are met when
performing the first test run. These are further
detailed in section
DANGER - First test run may
cause injury or damage! on page
Action
1.
DANGER!
Turn off all electric power, hydraulic and pneumatic
pressure supplies to the robot!
For Foundry Prime robots: Do not turn off the air
pressure to motors and SMB.
2.
esd
WARNING!
The unit is sensitive to ESD, before handling the unit
please observe the safety information in section
WARNING - The unit is sensitive to ESD! on page
35
3. Remove the SMB unit as detailed in
unit on page 273
4.5.1. Replacement of SMB unit
Note
Art. no. is specified in
equipment on page
Shown in the figure
unit on page
R1.SMB1-3, R1.SMB4-6 and R2.SMB
Shown in the figure
unit on page
Detailed in chapter Calibration -
section
Updating revolution counters
on page
378.
33.
Note
Removal, SMB
4 Repair
Continued
Required
273.
Location of SMB
273.
Location of SMB
273.
Continues on next page
275

Advertisement

Table of Contents
loading

Table of Contents