Error Message SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec]
SS_EID_EC_ER_IOP_STOPPED_DUE_TO_SIGNAL ) Internal error - signal caused stop
[chars].
Error Message
SS_EID_EC_ER_IOP_TERMINATED_ABNORMALLY ) Internal error - abnormal exit [chars].
Error Message
SS_EID_EC_ER_OPEN_MSG_QUEUE_FAILED ) Internal error - message queue [chars].
Error Message
SS_EID_EC_ER_PTHREAD_CREATE_FAILED ) Internal error - threads [chars].
OL-15956-01
Explanation
The I/O process stopped because of a signal received. Node was warm started because
of this error.
1. Ensure that the software is at the latest level on the cluster.2. Ask your
Recommended Action
customer support representative for assistance.
Introduced
Cisco MDS SAN-OS Release 1.3(1).
SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec]
The I/O process exited abnormally. Node was warm started because of this error.
Explanation
1. Ensure that the software is at the latest level on the cluster. 2. Ask your
Recommended Action
customer support representative for assistance.
Cisco MDS SAN-OS Release 1.3(1).
Introduced
SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec]
Explanation
The process cannot open the needed message queue. Node was rebooted because of this
error.
If this error is repeated continuously, follow these steps: 1. Reinstall the code
Recommended Action
on the node. The node will then have to be removed and added back to the cluster. 2. Ensure that the
software is at the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 1
with the latest level of code. 3. Ask your customer support representative for assistance, if the error
continues.
Introduced
Cisco MDS SAN-OS Release 1.3(1).
SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec]
The process cannot create the needed threads. Node was rebooted because of this error.
Explanation
If this error is repeated continuously, follow these steps: 1. Reinstall the code
Recommended Action
on the node. The node will then have to be removed and added back to the cluster. 2. Ensure that the
software is at the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 1
with the latest level of code. 3. Ask your customer support representative for assistance, if the error
continues.
Introduced