Cisco AJ732A - MDS 9134 Fabric Switch Messages Manual page 355

Cisco mds 9000 family system messages reference (ol-15956-01, april 20078)
Hide thumbs Also See for AJ732A - Cisco MDS 9134 Fabric Switch:
Table of Contents

Advertisement

Chapter 2
System Messages and Recovery Procedures for the Cisco MDS 9000 Family
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Error Message
SS_EID_IC_EV_NODE_DISENFRANCHISED ) Node missing [chars].
Error Message
SS_EID_PL_ER_CLUSTER_PATH_FAILURE ) Cluster path failure [chars].
Error Message
Processor change detected [chars].
Error Message
hard disk full [chars].
Error Message
Logical Fibre Channel port reported failed [chars].
OL-15956-01
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec]
A node is missing from the cluster.
Explanation
1. Check the status of the nodes and find the node with a status of offline. 2.
Recommended Action
Repair the failing node. When the repair has been completed, this error will automatically be marked
as fixed. 3. Check the node status. If all the nodes in the cluster are now online, but the error in the
log has not been marked as fixed, manually mark the error as fixed.
Cisco MDS SAN-OS Release 1.3(1).
Introduced
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec]
Explanation
A cluster path has failed. The node cannot communicate with all the other nodes in the
cluster.
1. Repair the Fibre Channel network fabric. 2. Check the status of the node
Recommended Action
port. If the status of the port shows as online, mark the error you have just repaired as fixed.
Introduced
Cisco MDS SAN-OS Release 1.3(1).
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_PL_ER_CPU_QUANTITY )
The Caching Services Module (CSM) is failing.
Explanation
1. Replace the CSM. 2. Check node status. If all nodes show a status of online,
Recommended Action
mark the error you have just repaired fixed.
Cisco MDS SAN-OS Release 1.3(1).
Introduced
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_PL_ER_DISK_FULL ) Node
Explanation
The error that is logged in the cluster error log indicates a software problem in the
cluster.
1. Ensure that the software is at the latest level on the cluster. 2. Delete files
Recommended Action
from the /dumps directory. 3. Run a configuration dump and a logged data dump. Save the dump
data. 4. Ask your customer support representative for assistance. 5. Mark the error you have just
repaired as fixed.
Cisco MDS SAN-OS Release 1.3(1).
Introduced
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_PL_ER_FC_ADAP_FAIL )
Explanation
No active and functioning logical Fibre Channel port was detected by the software.
Reload the node. If the problem persists, replace the Caching Services Module.
Recommended Action
Cisco MDS SAN-OS Release 1.3(1).
Introduced
Cisco MDS 9000 Family System Messages Reference
2-319